1148
|
Wed Nov 19 18:12:35 2008 |
rana | Configuration | IOO | new channel for MC drum modes |
I set up the lockin to take the MC Demod Board's Qmon signal, demodulate it at 27.5 kHz, and
put the output into a DAQ channel (I think its either MC_DRUM1 or MC1_TEMPS). However,
the MC_DRUM channel doesn't look like its getting anything in the DTT although it looked fine
on a scope. I used the 'sensitivity' setting of the lockin to make the demodulated signal
large enough but not so large that it would saturate the ADC (+/- 2V). |
4541
|
Mon Apr 18 21:09:45 2011 |
Jamie | Configuration | Computers | new control room machine: pianosa |
I've just installed the new control room machine: "pianosa". It is a replacement for the old sun machine "op440m" [0].
Hardware:
- dual dual-core Intel Core i7-2600 CPU @ 3.40GH, hyperthreaded to provide 8 effective cores
- 16G memory (4x 4G dimms)
- nVidia GF108 GeForce GT 430
It's now running Ubuntu 10.04 LTS 64bit. Unfortunately, the default 10.04 kernel is 2.6.32, which does not support pianosa's apparently very new network adapter, which is (from lspci):
00:19.0 Ethernet controller: Intel Corporation 82579LM Gigabit Network Connection (rev 04 )
To get around this I temporarily added a PCI nic so that I could get on the network. I then added the Ubuntu kernel team PPA archive and installed linux-image-2.6.38-2, which is new enough to have the needed network driver, but not completely bleeding edge:
sudo add-apt-repository ppa:kernel-ppa/ppa
sudo apt-get update
sudo apt-get install linux-image-2.6.38-2-generic linux-headers-2.6.38-2-generic
Once the built in nic was working I removed the temporary one. Everything seems to be working fine now.
I have not yet done any configuration to integrate pianosa into the CDS network. I'll do that tomorrow.
[0] op44m has been moved into the control room rack next to linux1, in headless mode. If there is still a need to run scripts that only run on solaris, op440m can still be accessed via ssh as normal. Hopefully we can fully decommission this machine soon.
[1] https://launchpad.net/~kernel-ppa/+archive/ppa |
4542
|
Mon Apr 18 21:14:53 2011 |
Jamie | Configuration | Computers | new control room machine: pianosa |
Also, op440m's Sun monitor did not work well with pianosa, so I'm lending pianosa my HP monitor until we can get a suitable replacement. |
4497
|
Thu Apr 7 11:51:13 2011 |
steve | Summary | SAFETY | new crane operator inaugurated |
Quote: |
Mike Caton of Konecranes inspected and loadtested all 3 of the 40m cranes at max reach trolley positions with 1 ton.
|
Konecrane representative gave crane operator training in the 40m. Koji has become a qualified, trained crane operator of the 40m lab. |
Attachment 1: P1070535.JPG
|
|
13164
|
Thu Aug 3 19:46:27 2017 |
Jamie | Update | CDS | new daqd restart procedure |
This is the daqd restart procedure:
$ ssh fb1 sudo systemctl restart daqd_*
That will restart all of the daqd services (daqd_dc, daqd_fw, daqd_rcv).
The front end mx_stream processes should all auto-restart after the daqd_dc comes back up. If they don't (models show "0x2bad" on DC0_*_STATUS) then you can execute the following to restart the mx_stream process on the front end:
$ ssh c1<host> sudo systemctl restart mx_stream
|
514
|
Tue Jun 3 10:40:27 2008 |
tobin | Configuration | Computers | new dataviewer |
Alex let me know the secret location of the latest dataviewer executable for Linux. It is:
http://www.ligo.caltech.edu/~aivanov/upload/dv/Control/dc3
If your linux dataviewer on linux2 has the "year field not filled in" bug, you should download this into /usr/local/bin/dc3 (after making a backup of that file).
It looks like there's no dataviewer installed on rosalba yet. We should figure out a better directory layout for the linux machines; currently dataviewer is installed locally on linux2. It should be in /cvs/cds/caltech/apps/linux/something so that all the linux machines see the same installation. |
9282
|
Thu Oct 24 17:26:35 2013 |
jamie | Update | CDS | new dataviewer installed; 'cdsutils avg' now working. |
I installed a new version of dataviewer (2.3.2), and at the same time fixed the NDSSERVER issue we were having with cdsutils. They should both be working now.
The problem turned out to be that I had setup our dataviewer to use the NDSSERVER environment, whereas by default it uses the LIGONDSIP variable. Why we have two different environment variables that mean basically exactly the same thing, who knows. |
9285
|
Thu Oct 24 23:12:21 2013 |
jamie | Update | CDS | new dataviewer installed; no longer works on Ubuntu 10 workstations |
Quote: |
I installed a new version of dataviewer (2.3.2), and at the same time fixed the NDSSERVER issue we were having with cdsutils. They should both be working now.
The problem turned out to be that I had setup our dataviewer to use the NDSSERVER environment, whereas by default it uses the LIGONDSIP variable. Why we have two different environment variables that mean basically exactly the same thing, who knows.
|
Dataviewer seems to run fine on Chiara (Ubuntu 12), but not on Rossa or Pianosa (Ubuntu 10), or Megatron, which I assume is also something medium-old.
We get the error:
controls@megatron:~ 0$ dataviewer
Can't find hostname `fb:8088'
Can't find hostname `fb:8088'; gethostbyname(); error=1
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Error in obtaining chan info.
Can't find hostname `fb:8088'
Can't find hostname `fb:8088'; gethostbyname(); error=1
Sadface :( We also get the popup saying "Couldn't connect to fb:8088" |
9287
|
Thu Oct 24 23:30:57 2013 |
jamie | Update | CDS | new dataviewer installed; no longer works on Ubuntu 10 workstations |
Quote: |
Quote: |
I installed a new version of dataviewer (2.3.2), and at the same time fixed the NDSSERVER issue we were having with cdsutils. They should both be working now.
The problem turned out to be that I had setup our dataviewer to use the NDSSERVER environment, whereas by default it uses the LIGONDSIP variable. Why we have two different environment variables that mean basically exactly the same thing, who knows.
|
Dataviewer seems to run fine on Chiara (Ubuntu 12), but not on Rossa or Pianosa (Ubuntu 10), or Megatron, which I assume is also something medium-old.
We get the error:
controls@megatron:~ 0$ dataviewer
Can't find hostname `fb:8088'
Can't find hostname `fb:8088'; gethostbyname(); error=1
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Warning: Not all children have same parent in XtManageChildren
Error in obtaining chan info.
Can't find hostname `fb:8088'
Can't find hostname `fb:8088'; gethostbyname(); error=1
Sadface :( We also get the popup saying "Couldn't connect to fb:8088"
|
Sorry, that was a goof on my part. It should be working now. |
4261
|
Tue Feb 8 15:22:13 2011 |
kiwamu | Update | Green Locking | new electronics rack at X end |
Yesterday I moved the whole green electronics stuff, which had been sitting on the floor at the X end, into a new electronics rack.
The rack now is placed under the cable rail close to the ETMX chamber.

|
1109
|
Mon Nov 3 19:18:47 2008 |
Alberto | Configuration | General | new elog |
Phil Ehrens kindly poured our elog's content in a CD that now is here at the 40m.
I've been trying to install the 2.7.5 version of the elog on Nodus, a Sun machine, but the installing procedure is different from linux and I dont' know it. I tried to recompile the elog from the source code but the way gcc is called must be wrong because I get this error message:
nodus:elog-2.7.5>make
gcc -DHAVE_SSL -o elog src/elog.c -lsocket -lnsl -lssl
src/elog.c:45:25: openssl/ssl.h: No such file or directory
src/elog.c:329: error: parse error before "SSL"
src/elog.c: In function `ssl_connect':
src/elog.c:331: error: `SSL_METHOD' undeclared (first use in this function)
src/elog.c:331: error: (Each undeclared identifier is reported only once
src/elog.c:331: error: for each function it appears in.)
src/elog.c:331: error: `meth' undeclared (first use in this function)
src/elog.c:332: error: `SSL_CTX' undeclared (first use in this function)
src/elog.c:332: error: `ctx' undeclared (first use in this function)
src/elog.c:340: error: `ssl_con' undeclared (first use in this function)
src/elog.c:341: error: `sock' undeclared (first use in this function)
src/elog.c: In function `retrieve_elog':
src/elog.c:383: error: `SSL' undeclared (first use in this function)
src/elog.c:383: error: `ssl_con' undeclared (first use in this function)
src/elog.c: In function `submit_elog':
src/elog.c:631: error: `SSL' undeclared (first use in this function)
src/elog.c:631: error: `ssl_con' undeclared (first use in this function)
make: *** [elog] Error 1
Joe, Yoichi, anyone else knows how to do that? |
1110
|
Mon Nov 3 21:38:32 2008 |
Yoichi | Configuration | General | new elog |
Quote: | I tried to recompile the elog from the source code but the way gcc is called must be wrong because I get this error message:
nodus:elog-2.7.5>make
gcc -DHAVE_SSL -o elog src/elog.c -lsocket -lnsl -lssl
src/elog.c:45:25: openssl/ssl.h: No such file or directory
src/elog.c:329: error: parse error before "SSL"
|
The location of ssl.h is a bit strange in the sunfreeware version of OpenSSL. Since elog does not use configure script, you have to
edit Makefile and add an appropriate -I option to an appropriate variable definition (probably LIBS or CFLAGS, because the elog Makefile does
not use INCLUDES).
If you don't understand what I'm saying, just wait for me. |
6666
|
Wed May 23 11:30:39 2012 |
steve | Update | PEM | new emergency back up lights installed |
New self checking emergency back up lights were installed at 13 locations in the 40m lab. |
Attachment 1: IMG_1217.JPG
|
|
13323
|
Wed Sep 20 15:49:26 2017 |
rana | Omnistructure | Computers | new internet |
Larry Wallace hooked up a new switch (Brocade FWS 648G) today which is our 40m lab interface to the outside world internet. Its faster.
He then, just now, switched over the cables which were going to the old one into the new one, including NODUS and the NAT Router. CDS machines can still connect to the outside world.
In the next week or two, he'll install a new NAT for us so that we can have high speed comm from CDS to the world. |
14464
|
Mon Feb 18 19:16:55 2019 |
rana | Summary | Computers | new laptop setup: ASIA |
The old IBM laptop (Asia) has died from a fan error after 7 years. WE have a new Lenovo 330 IdeaPad to replace it:
- to enter bios, the usual FN keys don't work. Power off laptop. Insert paperclip into small hole on laptop side with upside-down U symbol. Laptop powers up into BIOS setup.
- Insert SL 7.6 DVD into drive
- Change all settings from modern UEFI into Legacy support. Change Boot order to put CDROM first.
- Boot.
- Touchpad is not detected. Hookup mouse for setup.
- Delete windows partition.
- Setup wireless network according to (https://wiki-40m.ligo.caltech.edu/Network). Computer name = asia.martian.
- Set root password. Do not create user (we want to make the controls acct later using the command line so that we can set userID and groupID both to 1001).
- Begin install...lots of disk access noises for awhile...
Install done. Touchpad not recognized by linux - lots of forum posts about kernel patching...Arrgh! |
14624
|
Mon May 20 13:16:57 2019 |
gautam | Summary | Computers | new laptop setup: ASIA - ndscope and diaggui |
Following instructions here, I installed ndscope on this machine. DTT still could not be be run from this machine, and I want to use this today - so I ran the following commands from the K. Thorne setup instructions.
yum clean metadata
yum update
yum install cds-workstation pcaspy subversion redhat-lsb gnuradio google-chrome-stable xorg-x11-drv-nvidia epel-release redhat-lsb
Now diaggui can be opened, and spectra can be made. I'm moving this laptop to its new home at EY.
Quote: |
- now running 'yum install gds-all' to see if we need more local libraries to run GDS from the shared disks...
|
|
14543
|
Mon Apr 15 18:29:07 2019 |
rana | Summary | Computers | new laptop setup: ASIA - yum issues |
had trouble using YUM to update. This turned out to be a config problem with our Martian router, not the new laptop. Since I've changed the WiFi pwd awhile ago for the martian access for the CDS laptops, you'll have to enter that in order to use the laptops.
turned out to be some Access Control nonsense inside of the router. Even loggin in as admin with a cable gave some of the fields the greyed out color (had to hover over the link and then type the URL directly in the browser window). ASIA is now able to connect and use YUM + usual connections. Gautam and I have also moved the router a little to get easier view of its LED lights and not blockk its WiFi signal with the cable tray. We'll get a little shelf so that we can mount it ~1 foot off of the wall.
still, this seems like a bad laptop choice: the Lenovo Ideapad 330 will not have its touchpad supported by SL7 without compiling a new version of the kernel  |
14598
|
Wed May 8 22:11:46 2019 |
rana | Summary | Computers | new laptop setup: ASIA - yum issues |
- setup controls user using K Thorne LLO CDS offsite workstation instructions
- modified /etc/fstab ala pianosa to NFS mount disks
- set up symlinks as other workstations
- troubles with libsasl2 and libmetaio libraries as usual for SL7 - doing symlink tricks
- setup shared .bashrc
- now running 'yum install gds-all' to see if we need more local libraries to run GDS from the shared disks...
|
4412
|
Fri Mar 18 14:18:00 2011 |
kiwamu | Summary | General | new laser pointers |
Just for a record. We got 4 new laser pointers (2 greens, 1 blue, and 1 green and red combination). Don't lose them.
They reside in a bucket on the SP table, where IR viewers and sensor cards also reside.

|
4488
|
Tue Apr 5 17:31:59 2011 |
steve | Summary | General | new laser pointers |
Quote: |
Just for a record. We got 4 new laser pointers (2 greens, 1 blue, and 1 green and red combination). Don't lose them.
They reside in a bucket on the SP table, where IR viewers and sensor cards also reside.

|
Low power green-red laser pointers are in. High power green, red and blue pointers are confiscated. |
Attachment 1: P1070530.JPG
|
|
8717
|
Tue Jun 18 10:37:00 2013 |
Steve | Summary | General | new laser pointers |
Red-green laser pointers added to the depleted stock of 2011
The two pointers output measured 4.4 mW green and 2 mW red
|
13663
|
Fri Mar 2 01:45:06 2018 |
gautam | Update | ALS | new look ALS electronics |
I spent today making another daughter board (so that we can use the new scheme for I and Q for one arm), testing it (i.e. measuring noise and TF and comparing to LISO model), and arranging all of this inside the 1U demod chassis. To accommodate everything inside, I decided to remove the 2 unused demod units from inside the box. I then drilled a few holes, installed the daughter boards on some standoffs, removed the capacitors and inductors as I outlined yesterday, and routed input and output signals to/from the daughter board. The outputs are routed to a D-sub on the rear panel. More details + better photo + results of testing the combined demod+daughter board signal chain tomorrow... |
Attachment 1: IMG_6916.JPG
|
|
13666
|
Mon Mar 5 17:27:34 2018 |
gautam | Update | ALS | new look ALS electronics - characterization |
I did a quick test of the noise of the new ALS electronics with the X arm ALS. Attachment #1 shows the results - but something looks off in the measurement, especially the "LO driven, RF terminated" trace. I will have to defer further testing to tomorrow. Of course the real test is to digitize these signals and look at the spectrum of the phase tracker output, but I wanted a voltage noise comparison first. Also, note that I have NOT undone the whitening TFs of (z,p) = (15,150) on these traces. I wonder if these noisy signals (particularly the 10Hz multiple harmonics) are an artefact of measurement, or if something is wonky in the daughter board circuits themselves. I am measuring these with the help of a DB9 breakout board and some pomona minigrabbers. Reagrdless, the sort of ripple seen in the olive green trace for the I channel wasn't present when I did the same test with RF signal generators out on the electronics workbench, so I am inclined to think that this isn't a problem with the circuit. I'm measuring with the SR785 with the "A" input setting, but with the ground set to "Float". I need to look into what the difference is between this mode, and the "A-B" mode. At first glance, both seem to be equivalent differential measurements, but I wonder if there is some subtlety w.r.t. pickup noise.
Perhaps I can repeat the test at the output of the AA board. I looked into whether there is a spare +/- 24V DC power supply available at the LSC rack, to power the 1U AA chassis, but didn't see anything there. |
Attachment 1: BeatMouthX_20180305_diffOut.pdf
|
|
13668
|
Thu Mar 8 00:40:25 2018 |
gautam | Update | ALS | new look ALS electronics - characterization |
I am almost ready for a digital test of the new ALS electronics. Today, Koji and I spent some time tapping new +/-24VDC DIN terminal blocks at the LSC rack to facilitate the installation of the 1U differential receiving AA chassis (separate elog entry). The missing piece of the puzzle now is the timing adapter card. I opted against trying a test tonight as I am having some trouble bringing c1lsc back online.
Incidentally, a repeat of the voltage noise measurement of the X arm ALS beat looked much cleaner today, see Attachment #1 - I don't have a good hypothesis as to why sometimes the signal has several harmonics at 10Hz multiples, and sometimes it looks just as expected. The problem may be more systematically debuggable once the signals are being digitally acquired. |
Attachment 1: BeatMouthX_20180305_diffOut.pdf
|
|
1677
|
Tue Jun 16 09:02:30 2009 |
steve | Configuration | VAC | new maglev RGA scan |
The maglev fore line pressure is 3e-6 torr at CC2 after 4 days of pumping. Varian turbo V-70 is pumping on it through V4 and VM2
Actual pumping speed ~10 l/s for N2. There was no baking. The maglev performance looks good : 3e-9 torr on CC4 with RGA -region only. |
Attachment 1: nmagd4scan.jpg
|
|
Attachment 2: nmagd4.jpg
|
|
1690
|
Tue Jun 23 10:06:03 2009 |
steve | Update | VAC | new maglev RGA scan at day6 |
The Maglev is running for 10 days with V1 closed. The pressure at the RGA-region is at 2e-9 torr on CC4 cold cathode gauge.
Valve VM2 to Rga-only was opened 6 days ago. The foreline pressure is still 2.2e-6 torr with small Varian turbo ~10 l/s on cc2
Daily scans show small improvement in large amu 32 Oxygen and large amu 16, 17 and 18 H20 water peaks.
Argon calibration valve is leaking on our Ar cylinder and it is constant.
The good news is that there are no fragmented hydrocarbons in the spectrum.
The Maglev is soaked with water. It was seating in the 40m for 4 years with viton o-ring seals
However I can not explan the large oxygen peak, either Rai Weiss can not.
The Maglev scans are indicating cleanliness and water. I'm ready to open V1 to the IFO |
Attachment 1: newmagscand6.jpg
|
|
Attachment 2: nmagpresd10.jpg
|
|
1671
|
Fri Jun 12 09:56:38 2009 |
steve | Configuration | VAC | new maglev installed |
Joe and Steve
The retrofitted Osaka 390 was installed on the pumpspool yesterday.
V1 gate valve is disabled for safety by disconnected pneumatic power plug.
The foreline of this maglev now have a KF25 size viton o-ring directly on the turbo.
This is bad for leak hunting.
Joe is ready with new interface cable. Power supply and cables are in place.
The maglev was pumped down this morning.
All new gas kits and metal hose were leak checked by sprayed methanol.
There is no obvious sign of leak. I was expecting the pressure to drop below 1e-5 Torr in one hour.
TP2 is drying out the levitating coils of the turbo at ~7 l/s for N2
We'll start the pump as soon as Joe is in.
|
Attachment 1: m390pd.jpg
|
|
4339
|
Tue Feb 22 23:11:42 2011 |
valera | Update | | new medm screens: C1ASS.adl and C1MCASS.adl |
|
Attachment 1: C1MCASS.jpeg
|
|
Attachment 2: C1ASS.jpeg
|
|
1421
|
Tue Mar 24 13:10:07 2009 |
Alberto | Configuration | PSL | new mirror installed on the AP table |
New flipping mirror installed on the AP table on the beam path to the REFL199 PD.
If you're missing the double demod signal, please check that it is actually down. |
2016
|
Tue Sep 29 01:50:10 2009 |
rob | Configuration | LSC | new modulation frequencies |
Mode cleaner length measured tonight.
33196198
132784792
165980990
199177188
[Tag by KA: modulation frequency, MC length] |
509
|
Sun Jun 1 19:25:10 2008 |
rana | Configuration | Computers | new monitor on op440m |
I installed the new 24" flat screen on op440m. I increased the screen resolution from 1280x1024 to 1900x1200 using
the obscure 'fbconfig' command. You can type Google it if you want.
The old monitor is on the surplus cart. If you are reading this and think you might walk from the 40 over to
Bridge, please wheel the cart full of old computer equipment (on the north side of the control room) over to Larry.
I also copied over all the images on the D40 to a folder on Kirk's computer and deleted the originals.
Dan Busby also visited us last week to help us move the drill press from the Y arm down into the sub basement
of W Bridge. |
Attachment 1: Andrey-440.jpg
|
|
Attachment 2: Busby08.jpg
|
|
9741
|
Thu Mar 20 11:16:16 2014 |
Steve | Update | General | new projector |
[ Manasa, Ericq and Steve ]
Vivitek D952HD with 186 hours installed. |
8010
|
Wed Feb 6 15:10:22 2013 |
Steve | Update | PEM | new safety signs on exterier doors |
Quote: |
Quote: |
The wood exteier walls, gutters and doors were painted at CES-Annex building #69
|
The east and south end of the 40m emergency exit doors are sealed- tapped off temporarily. They will be painted on the out side only. This job will be done by tomorrow noon
Do not open chamber if you smell the paint !
|
The east and south end of the 40m emergency exit doors received new safety signs. |
Attachment 1: IMG_0068.JPG
|
|
148
|
Fri Nov 30 19:29:14 2007 |
rana | Configuration | SUS | new screen |
Andrey is working on a new screen to show us the drift of the optics by alarming on
their osem values. You can find it under SUS as 'Drift Mon' from the site map.
To aid in this I ran the following csh commands which effect all optics:
foreach opt (ETMX ETMY ITMX ITMY MC1 MC2 MC3 BS PRM SRM)
foreach dof (POS PIT YAW)
ezcawrite C1:SUS-${opt}_SUS${dof}_INMON.PREC 0
end
end
This should make the DOF readouts more readable. |
376
|
Thu Mar 13 13:15:09 2008 |
aivanov | Update | Computer Scripts / Programs | new sfotware intall, backup files |
New:
op440m:40m>ls -alt /cvs/cds/caltech/target/c1susvme[12]/*.o
-rw-r--r-- 1 controls staff 57920 2008-03-13 13:11 /cvs/cds/caltech/target/c1susvme2/losLinux2.o
-rw-r--r-- 1 controls staff 57976 2008-03-13 13:11 /cvs/cds/caltech/target/c1susvme1/losLinux1.o
op440m:40m>ls -alt /cvs/cds/caltech/target/c1isce[xy]/*.o
-rw-r--r-- 1 controls staff 246861 2008-03-13 13:12 /cvs/cds/caltech/target/c1iscey/losEtmy.o
-rw-r--r-- 1 controls staff 246861 2008-03-13 13:12 /cvs/cds/caltech/target/c1iscex/losEtmx.o
op440m:40m>ls -alt /cvs/cds/caltech/target/c0dcu1/*.o
-rw-r--r-- 1 controls staff 63547 2008-03-12 14:57 /cvs/cds/caltech/target/c0dcu1/dcuDma.o
Backups:
op440m:40m>ls -alt /cvs/cds/caltech/target/c1susvme[12]/*.o.13mar08
-rw-r--r-- 1 controls staff 55960 2005-06-21 13:30 /cvs/cds/caltech/target/c1susvme2/losLinux2.o.13mar08
-rw-r--r-- 1 controls staff 55960 2005-06-21 13:30 /cvs/cds/caltech/target/c1susvme1/losLinux1.o.13mar08
op440m:40m>ls -alt /cvs/cds/caltech/target/c1isce[xy]/*.o.13mar08
-rw-r--r-- 1 controls staff 229793 2007-03-08 11:09 /cvs/cds/caltech/target/c1iscex/losEtmx.o.13mar08
-rw-r--r-- 1 controls staff 229793 2007-03-08 11:09 /cvs/cds/caltech/target/c1iscey/losEtmy.o.13mar08
op440m:40m>ls -alt /cvs/cds/caltech/target/c0dcu1/*.o.12mar08
-rw-r--r-- 1 controls staff 60810 2004-09-08 08:47 /cvs/cds/caltech/target/c0dcu1/dcuDma.o.12mar08 |
994
|
Thu Sep 25 17:14:31 2008 |
rana | Configuration | General | new sitemap |
|
Attachment 1: vegemite.png
|
|
4551
|
Thu Apr 21 14:39:43 2011 |
steve | Update | RF System | new strain relieved N connectors at AP |
New right angle PVC, 2 x 2 x 1/4" installed at the AP table to strain relief the 1/4" spiral corrugated RF coaxes. |
Attachment 1: P1070562.JPG
|
|
Attachment 2: P1070564.JPG
|
|
12650
|
Wed Nov 30 14:53:56 2016 |
Steve | Update | SUS | new sus wire stored in N2 filled dessicator |
The new SOS sus wire finally is stored in a nitrogen filled dessicator. This was recommended by Ca. Fine Wire to minimize the aging - oxidation.
The dessicator was pumped down with " aux-drypump " to 1 Torr and than filled up with N2 to 760 Torr. This was repeated 2x and the dessicator was sealed off. |
Attachment 1: dessicatorC.jpg
|
|
Attachment 2: wireN2c.jpg
|
|
10628
|
Tue Oct 21 17:44:28 2014 |
jamie | Omnistructure | Computer Scripts / Programs | new version of cdsutils (351) installed |
I just installed cdsutils r351 at /ligo/apps/linux-x86_64/cdsutils. It should be available on all workstations.
It includes a bunch of bug fixes and feature improvements, including the step stuff that Rana was complaining about. |
10655
|
Thu Oct 30 16:25:22 2014 |
ericq | Omnistructure | Computer Scripts / Programs | new version of cdsutils (361) installed |
Quote: |
I just installed cdsutils r351 at /ligo/apps/linux-x86_64/cdsutils. It should be available on all workstations.
It includes a bunch of bug fixes and feature improvements, including the step stuff that Rana was complaining about.
|
Cdsutils r361 installed, for the "avg" updates. aLOG
|
2763
|
Sun Apr 4 17:32:07 2010 |
Alberto | Metaphysics | General | new y-arm? |
Quote: |
There's several more of the this vintage in one of the last cabinets down the new Y-arm.
|
Hold on, did the arms get re-baptized? |
15304
|
Wed Apr 15 15:15:17 2020 |
Chub | Update | VAC | nitrogen cylinders delivered |
Four nitrogen cylinders replaced the empties in the rack at the west entrance. Additionally, Airgas will now deliver only once a week. Let me know via email or text when the there are four empties in the rack and I'll order the next round. |
9221
|
Tue Oct 8 11:29:30 2013 |
Steve | Update | PEM | no Janitor day today |
This was the second week without wet mopping the floor and wet wipe down of the vacuum envelope.
We changed filters on the 40m "HEPA" vacuum pump. It still has very dirty exhaust. Do not use it in clean room! |
Attachment 1: dirtyVacpump.jpg
|
|
4784
|
Fri Jun 3 18:12:03 2011 |
steve | Update | Computers | no PEM channels |
AA filter box was removed and modified at 1Y7 today. The -5V power supply was current limited when I plugged it back in. It was removed for medical attention.
NO PEM channels available! because of this.
|
3941
|
Wed Nov 17 20:44:59 2010 |
yuta | Summary | CDS | no QPD channels on c1sus machine today |
(Joe, Suresh, Yuta)
Currently, only 2 ADC cards work on c1sus machine.
No QPD inputs(e.g. MC2 trans), and no RFM.
Summary:
We wanted to have PEM(physical environment montor) channels, so we moved a ADC card in c1sus machine.
It ended up with destroying one of the 3 ADCs.
What we did:
1. Moved ADC card at PCIe expansion board slot 0 to other empty slot.
What we call PCI slot 0 was "DO NOT USE" in LIGO-T10005230-v1, so we moved it.
2. Connected that ADC card to PEM channel box at 1X7 via SCSI cable.
3. ADC card order is changed, so we checked ADC number assinging and re-labeled the cable.
4. Found RFM is not working(c1sus and c1ioo not talking) and fb is in a weird state(Status: 0x4000 in GDS screens)
5. Swapped the cabling so that ADC card 0 will be connected to timing interface card at slot1, but didn't help.
More than that, we suffered ADC timeout.
6. Tried ADC card swapping, slot position changing, taking out some of the ADC cards, etc.
We found that ADC timeout doesn't happen with 2 ADC cards.
But if we connect one of the ADC card to the timing interface card at slot 8, c1sus ADC timeouts with 2 ADC cards, too.
So, I think that timing interface card is bad.
7. Stopped rebooting c1sus again and again. We decided to investigate the problem tomorrow.
We only need ADC card 0 and 1 for MC damping.(see this wiki page)
ADC card 0: all UL/UR/LR/LL SENs
ADC card 1: all SD SENs
ADC card 2: all QPDs
Result:
We can damp optics and lock MC.
We can't do A2L because RFM is not working.
We can't see MC2 trans because we currently don't have ADC card 2. |
5741
|
Wed Oct 26 10:07:16 2011 |
steve | Update | General | no electricity ....... will be recheduled |
Quote: |
Subject: Electricity Interruption- 11/19/11
From: "PP Service Center" <PPService@caltech.edu>
To: "DeLaRosa, Dario" <Dario.DeLaRosa@caltech.edu>,
...snip... "Sullivan, Joan O." <sully@caltech.edu> |
CALIFORNIA INSTITUTE OF TECHNOLOGY
FACILITIES MANAGEMENT
UTILITY & SERVICE INTERRUPTION
**PLEASE POST**
Building: Central Engineering Services (C.E.S.)
LIGO Gravitational Physics building adjacent to C.E.S.
Safety Storage adjacent to CES
Steele House
Keck Lab
Date: November 19, 2011
Time: 8:00 a.m. To 9:00 a.m.
Interruption: Electricity
Contact: Mike Anchondo ext. 4999 Tom Brennan 4984
*This interruption is required for maintenance of high voltage switchgear in Campus Sub Station.
|
CANCELLED, WILL BE RESCHEDULED* |
5728
|
Mon Oct 24 14:26:01 2011 |
steve | Update | General | no electricity on Nov. 19 |
Subject: Electricity Interruption- 11/19/11
From: "PP Service Center" <PPService@caltech.edu>
To: "DeLaRosa, Dario" <Dario.DeLaRosa@caltech.edu>,
...snip... "Sullivan, Joan O." <sully@caltech.edu> |
CALIFORNIA INSTITUTE OF TECHNOLOGY
FACILITIES MANAGEMENT
UTILITY & SERVICE INTERRUPTION
**PLEASE POST**
Building: Central Engineering Services (C.E.S.)
LIGO Gravitational Physics building adjacent to C.E.S.
Safety Storage adjacent to CES
Steele House
Keck Lab
Date: November 19, 2011
Time: 8:00 a.m. To 9:00 a.m.
Interruption: Electricity
Contact: Mike Anchondo ext. 4999 Tom Brennan 4984
*This interruption is required for maintenance of high voltage switchgear in Campus Sub Station.
|
5827
|
Mon Nov 7 08:25:15 2011 |
steve | Update | General | no electricity on Nov. 20 |
The Nov.19 interruption was rescheduled to be on Nov.20,2011
CALIFORNIA INSTITUTE OF TECHNOLOGY
FACILITIES MANAGEMENT
UTILITY & SERVICE INTERRUPTION
**PLEASE POST**
Building: CENTRAL ENGINEERING SERVICES, STEELE HOUSE, KECK LAB,
LIGO GRAVITATION PHYSICS BLDG, SAFETY STORAGE (BY CES)
Date: Sunday, Nov. 20,2011
Time: 10:00 AM TO 11:00 AM
Interruption: ELECTRICITY
Contact: MIKE ANCHONDO X-4999 OR TOM BRENNAN X-4984
*THIS INTERRUPTION IS REQUIRED FOR MAINTENANCE OF HIGH VOLTAGE SWITCHGEAR
IN CAMPUS SUB-STATION. |
4867
|
Thu Jun 23 21:34:21 2011 |
kiwamu | Update | CDS | no foton on the CentOS machines |
For some reasons foton's deafault sample rate is NOT correct when it runs on the CentOS machines.
It tries to setup the sample rate to be 2048 Hz instead of 16384 Hz until you specify the frequency.
To avoid an accidental change of the sample rate,
running foton on CentOS is forbidden until any further notifications.
Run foton only on Pianosa.
Additionally I added an alias sentence in cshrc.40m such that people can not run foron on CentOS (csh and tcsh, technically speaking).
Below is an example of raw output when I typed foron on a CentOs machine.
rossa:caltech>foton
DO NOT use foton on CentOS
|
3750
|
Thu Oct 21 05:51:10 2010 |
kiwamu | Update | Locking | no green beat note |
Still I didn't see any beat note signals..
With a help from Suresh, Yuta and Rana, I tried searching for the green beat note by changing the temperature of the X end NPRO.
The noise level after it goes through an RF amplifier (G=23dB) was about -70dBm at 50MHz.
This noise may cover the beat note signal.
I am going to post some details later. |