Entry  Sat May 24 22:56:57 2014, Jenne, Update, Electronics, Amplifier removed from BeatX path 
    Reply  Mon May 26 07:59:23 2014, Koji, Update, Electronics, Amplifier removed from BeatX path 
       Reply  Tue May 27 11:58:45 2014, Jenne, Update, Electronics, Amplifier removed from BeatX path ALS_outofloop_27May2013.pdf
Message ID: 9991     Entry time: Sat May 24 22:56:57 2014     Reply to this: 9992
Author: Jenne 
Type: Update 
Category: Electronics 
Subject: Amplifier removed from BeatX path 

I just realized that I forgot to elog this, but yesterday afternoon I bypassed the amplifier in the BeatX path, and now the X beatnote is about -27dBm.  Arms lock nicely with ALS.