40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Feb 28 11:20:51 2012, steve, Update, SAFETY, safety audit 2012 safety12.JPG
    Reply  Fri Mar 30 09:37:13 2012, steve, Update, SAFETY, safety audit 2012 CORRECTIONS 
       Reply  Wed Mar 6 11:33:09 2013, steve, Update, SAFETY, safety audit 2013 IMG_0010.JPG
          Reply  Wed Mar 13 16:04:24 2013, steve, Update, SAFETY, laser safety glasses checked safetyglasseschecked.jpg
             Reply  Wed Feb 19 08:07:01 2014, steve, Update, safety, annual laser safety glasses check  AA2014checked.jpg2014check.jpg
                Reply  Tue Feb 25 16:54:57 2014, steve, Update, safety, safety audit 2014 
                   Reply  Thu Feb 27 13:11:13 2014, steve, Update, safety, safety audit correction noDaisyChaining.jpgZbThumbnail.info
                   Reply  Thu Mar 13 16:05:48 2014, steve, Update, safety, safety audit 2014 T1400198-v1-CIT-LIGO_Labs_Annual_Safety_Audit_2014.pdf
                      Reply  Mon Mar 17 10:50:58 2014, steve, Update, safety, 2014 annual crane certification 2014craneCert.jpg
                         Reply  Thu Oct 2 14:36:52 2014, steve, Update, PEM, oil drops on vertex crane VertexOilDrops.jpg
                      Reply  Mon Apr 28 17:27:29 2014, steve, Update, safety, safety audit 2014 
                         Reply  Tue Apr 29 00:11:03 2014, steve, Update, safety, safety audit 2014 
                            Reply  Fri May 2 08:15:54 2014, steve, Update, safety, safety audit 2014 solidCoverRequired.jpg
          Reply  Tue Mar 19 10:30:00 2013, steve, Update, SAFETY, crane inspection 2013 sippingOIL.jpg03191301.PDF
          Reply  Fri May 31 10:25:17 2013, steve, Update, safety, first aid kits refilled refilledFAidK.jpg
             Reply  Thu Jun 6 16:33:19 2013, steve, Update, safety, updated laser inventory ELSOconnected.jpg
          Reply  Fri Aug 30 08:08:29 2013, steve, Update, safety, fire horns-flashers tested OK 
Message ID: 9900     Entry time: Fri May 2 08:15:54 2014     In reply to: 9873
Author: steve 
Type: Update 
Category: safety 
Subject: safety audit 2014 

 

 Late adition: CHECK all viewport covers.

A, transparent Lexan sheet is protecting glass windows in a horizontal position

B, metal housing protection is required on each viewport except signal ports

C, signal ports should be shielded by optical table enclosure

 

We have to cover this window-camera with implosion proof cover or just remove it and blank it.

Question number 2: Do our vertically positioned windows with flip able covers require protective lexan ? NO 5-5-2014

Attachment 1: solidCoverRequired.jpg  58 kB  Uploaded Fri May 2 10:47:09 2014  | Hide | Hide all