40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 9883     Entry time: Wed Apr 30 18:06:06 2014
Author: jamie 
Type: Update 
Category: CDS 
Subject: POP QPD signals now on dolphin 

The POP QPD X/Y/SUM signals, which are acquired in c1ioo, are now being broadcast over dolphin.  c1ass was modified to pick them up there as well:

c1ioo-POPQPD.pngc1ass-POPQPD.png

Here are the new IPC entries:

controls@fb ~ 0$ egrep -A5 'C1:IOO-POP' /opt/rtcds/caltech/c1/chans/ipc/C1.ipc
[C1:IOO-POP_QPD_SUM]
ipcType=PCIE
ipcRate=16384
ipcHost=c1ioo
ipcNum=116
desc=Automatically generated by feCodeGen.pl on 2014_Apr_30_17:33:22
--
[C1:IOO-POP_QPD_X]
ipcType=PCIE
ipcRate=16384
ipcHost=c1ioo
ipcNum=117
desc=Automatically generated by feCodeGen.pl on 2014_Apr_30_17:33:22
--
[C1:IOO-POP_QPD_Y]
ipcType=PCIE
ipcRate=16384
ipcHost=c1ioo
ipcNum=118
desc=Automatically generated by feCodeGen.pl on 2014_Apr_30_17:33:22
controls@fb ~ 0$ 

Both c1ioo and c1ass were rebuild/install/restarted, and everything came up fine.

The corresponding cruft was removed from c1rfm, which was also rebuild/installed/restarted.

ELOG V3.1.3-