40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu Apr 17 11:00:54 2014, jamie, Update, CDS, failed attempt to get Dolphin working on c1ioo 
    Reply  Thu Apr 17 16:59:45 2014, jamie, Update, CDS, slightly more successful attempt to get Dolphin working on c1ioo 
       Reply  Wed Apr 30 17:07:19 2014, jamie, Update, CDS, c1ioo now on Dolphin network dolphin.pngALSXonDolphin.pdf
          Reply  Wed Apr 30 17:45:34 2014, jamie, Update, CDS, c1ioo now on Dolphin network 
          Reply  Thu May 1 10:23:42 2014, jamie, Update, CDS, c1ioo dolphin fiber nicely routed green.png
             Reply  Fri May 2 01:01:28 2014, rana, Update, CDS, c1ioo dolphin fiber nicely routed 
                Reply  Fri May 2 11:14:47 2014, jamie, Update, CDS, c1ioo dolphin fiber nicely routed 
             Reply  Tue May 6 10:22:28 2014, steve, Update, CDS, c1ioo dolphin fiber  dolphin1x2.png
                Reply  Tue May 6 10:31:58 2014, jamie, Update, CDS, c1ioo dolphin fiber  
Message ID: 9881     Entry time: Wed Apr 30 17:07:19 2014     In reply to: 9824     Reply to this: 9882   9890
Author: jamie 
Type: Update 
Category: CDS 
Subject: c1ioo now on Dolphin network 

The c1ioo host is now fully on the dolphin network!

After the mx stream issue from two weeks ago was resolved and determined to not be due to the introduction of dolphin on c1ioo, I went ahead and re-installed the dolphin host adapter card on c1ioo.  The Dolphin network configurations changes I made during the first attempt (see previous log in thread) were still in place.  Once I rebooted the c1ioo machine, everything came up fine:

dolphin.png

We then tested the interface by making a cdsIPCx-PCIE connection between the c1ioo/c1als model and the c1lsc/c1lsc model for the ALS-X beat note fine phase signal.  We then locked both ALS X and Y, and compared the signals against the existing ALS-Y beat note phase connection that passes through c1sus/c1rfm via an RFM IPC:

The signal is perfectly coherent and we've gained ~25 degrees of phase at 1kHz.  EricQ calculates that the delay for this signal has changed from:

ALSXonDolphin.pdf

122 us -> 61 us 

I then went ahead and made the needed modifications for ALS-Y as well, and removed ALS->LSC stuff in the c1rfm model.

Next up: move the RFM card from the c1sus machine to the c1lsc machine, and eliminate c1sus/c1rfm model entirely.