40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Mar 28 20:23:02 2014, rana, Summary, IOO, MC2 moved 
    Reply  Mon Mar 31 11:34:00 2014, manasa, Summary, IOO, MC2 moved 
       Reply  Thu Apr 10 10:52:15 2014, manasa, Summary, IOO, MC2_TRANS path in WFS servo 
       Reply  Fri Apr 25 23:08:57 2014, rana, Summary, IOO, MC2_TRANS QPD Servo re-re-engaged again 
          Reply  Sat Apr 26 13:19:59 2014, ericq, Summary, IOO, MC2_TRANS QPD Servo re-re-engaged again 
          Reply  Mon Apr 28 15:47:57 2014, manasa, Summary, IOO, MC2_TRANS QPD Servo trend MC_TRANSservoApr28.png
             Reply  Mon Apr 28 20:31:38 2014, rana, Summary, IOO, MC2_TRANS QPD Servo trend Untitled.png
                Reply  Wed Apr 30 21:57:07 2014, rana, Summary, IOO, MC2_TRANS QPD Servo now on for real dolphin.pngMC2_QPD_trend.png
Message ID: 9869     Entry time: Mon Apr 28 15:47:57 2014     In reply to: 9857     Reply to this: 9871
Author: manasa 
Type: Summary 
Category: IOO 
Subject: MC2_TRANS QPD Servo trend 

Quote:

We turned on the MC2_TRANS paths for both PIT/YAW tonight.

I turned off the BLP200 and turned on the RLP7 (RLP always are better than BLP). G_PIT = -0.111, G_YAW = 0.111. On Monday, let's let Steve look at the trends and determine if this centering servo is bad or good.

The MC was showing slow but periodic alignment drifts and eventually unlocked around noon. I looked up the alignment trend (Attach: 2 day trend)

MC_TRANS_PIT_ERR and MC_TRANS_Y_ERR show that the MC_TRANS servo slowly drifted the IMC alignment causing it to lose lock from time to time (mostly in yaw).

To confirm that the drift was NOT due to off-centering in the MC2_TRANS QPD, I turned off the WFS servo, moved MC2 to recenter the trans beam on the QPD, and re-enabled WFS servo.

MC_TRANS path in WFS is still left enabled.