Thu Apr 17 17:15:54 2014, jamie, Update, CDS, mx_stream not starting on c1ioo
|
Thu Apr 17 17:22:32 2014, Jenne, Update, CDS, mx_stream not starting on c1ioo, locking okay
|
Fri Apr 18 14:00:48 2014, rolf, Update, CDS, mx_stream not starting on c1ioo
|
Fri Apr 18 19:05:17 2014, jamie, Update, CDS, mx_stream not starting on c1ioo
|
|
Message ID: 9831
Entry time: Fri Apr 18 19:05:17 2014
In reply to: 9830
|
Author: |
jamie |
Type: |
Update |
Category: |
CDS |
Subject: |
mx_stream not starting on c1ioo |
|
|
Quote: |
To fix open-mx connection to c1ioo, had to restart the mx mapper on fb machine. Command is /opt/mx/sbin/mx_start_mapper, to be run as root. Once this was done, omx_info on c1ioo computer showed fb:0 in the table and mx_stream started back up on its own.
|
Thanks so much Rolf (and Keith)! |