Message ID: 9806     Entry time: Mon Apr 14 11:19:55 2014
Author: Jenne 
Type: Update 
Category: LSC 
Subject: MC WFS found off 

I'm not sure why, but the WFS were turned off when I came in this morning.  The MC was not staying locked, and even during brief locks, the FSS FAST out was railed at 10. 

Aligning the MC mirrors to maximize the transmission, and then engaging the WFS seems to have made things better.