Entry  Fri Apr 11 01:02:07 2014, Jenne, Update, LSC, CARM and DARM both on IR signals!!!!!!!!! onlyIRspectra.pdf
    Reply  Fri Apr 11 02:09:31 2014, Jenne, Update, LSC, CARM and DARM both on IR signals!!!!!!!!! IRlocks.pdf
       Reply  Fri Apr 11 11:58:24 2014, Jenne, Update, LSC, CARM and DARM both on IR signals!!!!!!!!! DARM_IN1_getsSmaller.pngDARM_CARM_TRX_TRY.pngCARMtransition_DARMtransition.pngDARMin_DARMout.pngCARM_DARM_in_out.png
          Reply  Fri Apr 11 12:21:27 2014, Koji, Update, LSC, CARM and DARM both on IR signals!!!!!!!!! 
             Reply  Fri Apr 11 12:32:33 2014, ericq, Update, LSC, CARM and DARM both on IR signals!!!!!!!!! 
                Reply  Fri Apr 11 14:57:53 2014, steve, Update, LSC, congratulation whenSheisHappy3h.pngmc4hArms3hrs.png
                   Reply  Fri Apr 11 16:04:31 2014, Koji, Update, LSC, congratulation 
          Reply  Sun Apr 13 13:03:34 2014, rana, Update, LSC,  
    Reply  Fri Apr 11 10:30:48 2014, jamie, Update, LSC, CARM and DARM both on IR signals!!!!!!!!! 
Message ID: 9801     Entry time: Fri Apr 11 12:32:33 2014     In reply to: 9800     Reply to this: 9802
Author: ericq 
Type: Update 
Category: LSC 
Subject: CARM and DARM both on IR signals!!!!!!!!! 

Quote:

How much was the whitening gain for AS55 this time? 

 21 dB. We played with the whitening gain a little bit; at around 30dB with the signal levels at TRX = .1ish, we were consistently saturating the ADC. 