Entry  Tue Apr 8 19:10:39 2014, rana, Update, LSC, arm length measurements 
    Reply  Tue Apr 8 23:04:14 2014, manasa, Update, LSC, arm length measurements 
       Reply  Fri Apr 11 18:55:28 2014, manasa, Update, LSC, arm length measurements Xarm.pngYarm.png40mCavLength.zip
Message ID: 9789     Entry time: Tue Apr 8 19:10:39 2014     Reply to this: 9790
Author: rana 
Type: Update 
Category: LSC 
Subject: arm length measurements 

 Since we don't have an arm length precision measurement (i.e. better than centimeters), why not just do as Koji suggests and use the ALS to get the frequency spacing between a few red FSR and then we have the measurement solid ?