As far as I know the system is running as usual. I had the IMC locked and one of the arm flashing.
But the other arm had no flash and none of the arms were locked before kunch time.
This morning Steve and I went around the lab to turn on the realtime machines.
Also we took the advantage of this opportunity to shutdown linux1 and nodus
to replace the extension cables for their AC power.
I also installed a 3TB hard disk on linux1. This was to provide a local daily copy of our
working are. But I could not make the disk recognized by the OS.
It seems that there is a "2TB" barrier that the disk bigger than 2.2TB can't be recognized
by the older machines. I'll wait for the upgrade of the machine.
Rebooting the realtime machines did not help FB to talk with them. I fixed them.
Basically what I did was:
- Stop all of the realtime codes by running rtcds kill all on c1lsc, c1ioo, c1sus, c1iscex, c1iscey
- run sudo ntpdate -b -s -u pool.ntp.org on c1lsc, c1ioo, c1sus, c1iscex, c1iscey, and fb
- restart realtime codes one by one. I checked which code makes FB unhappy. But in reality
FB was happy with all of them running.
Then slow machines except for c1vac1 and c1vac2 were burtrestored.
-------
Zach reported that svn was down. I went to the 40m wiki and searched "apache".
There is an instruction how to restart apache. |