I tried to repeat Koji's PRMI lock using REFL165I/Q. I was not able to lock PRMI stably. All I could get was momentary PRMI sb locks (few seconds) using AS55Q for MICH and REFL165Q for PRMI. I tried to transition MICH locks from AS55Q to REFL165I/Q and this did not work well; I lost even the momentary locks.
The demod phases for both AS55 and REFL165 were also very different.
Input ports:
AS55 WHTN: 21dB demod phase -78.7deg
REFL165 WHTN: 45dB demod phase -80.7deg
Input matrix:
AS55Q x1.00 MICH
REL165Q x+0.14
Triggers:
MICH POP110I 100up/10down / FM Trig FM2/3/6/7/9 35up 2down 5sec delay
PRCL POP110I 100up/10down / FM Trig FM2/3/6/9 35up 2down 0.5sec delay
Servo:
MICH OFS 0.0 / Gain -10 / Limiter ON
PRCL OFS 0 / Gain -0.023 / Limiter ON
Output matrix:
MICH ITMX -1.0 / ITMY +1.0
PRCL PRM 1.0
|