40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Nov 12 15:18:34 2007, rob, Update, PSL, ISS ISS.png
    Reply  Mon Nov 12 23:44:19 2007, John, Update, PSL, ISS ISSfilter.jpg
Message ID: 96     Entry time: Mon Nov 12 15:18:34 2007     Reply to this: 97
Author: rob 
Type: Update 
Category: PSL 
Subject: ISS 

After John soldered a 3.7 MHz notch filter onto the ISS board, I took a quick TF and RIN measurement. The out-of-loop RIN is attached, including a dark noise trace, and with the gain slider at 10dB. The UGF is 35kHz with a phase margin of 30deg. John is currently doing a more thorough inspection, and will detail his findings in a subentry.
Attachment 1: ISS.png  9 kB  | Show | Show all
ELOG V3.1.3-