I've asked Manasa and Q to have a look at the MC in the morning. Rana and I have found it to be slightly uncooperative in relocking after a lockloss.
The concern is that we may be (by actuating on things during lock, or during a lockloss) ringing up some mode, maybe a violin mode in one of the suspensions, maybe a PZT mode of some sort. If we are, and then we have to push with the PZT on the laser to lock things, that may be why the laser's PZT RMS (on the FSS screen) is so often above 1Vrms. When we close the PSL shutter, the rms is low, like 0.6 or something, and it stays flat. As we've all see many a' time, the red trace on the top projector plot is pretty erratic throughout the day when the MC is locked or trying to lock.
We have found that just letting the autolocker go doesn't seem to work very well, and sometimes the MC just doesn't want to re-lock. Closing the PSL shutter or disabling the autolocker for a few minutes (5ish) doesn't do anything, but leaving it closed for a long time (30 ish minutes) helps a lot. The MC will relock immediately after a nice long break.
|