Tue Jan 7 22:44:45 2014, Jenne, Update, CDS, daqd on fb is segfaulting every ~30 seconds
|
Tue Jan 7 23:08:01 2014, jamie, Update, CDS, /frames is full, causing daqd to die
|
Tue Jan 7 23:13:47 2014, jamie, Update, CDS, /frames is full, causing daqd to die
|
Tue Jan 7 23:50:27 2014, jamie, Update, CDS, /frames space cleared up, daqd stabilized
|
Tue May 13 17:45:21 2014, rana, Update, CDS, /frames space cleared up, daqd stabilized
|
Thu May 15 01:42:07 2014, rana, Update, CDS, /frames space cleared up, daqd stabilized
|
|
Message ID: 9535
Entry time: Tue Jan 7 23:50:27 2014
In reply to: 9533
Reply to this: 9949
|
Author: |
jamie |
Type: |
Update |
Category: |
CDS |
Subject: |
/frames space cleared up, daqd stabilized |
|
|
The wiper script is done and deleted a whole bunch of stuff to clean up some space:
controls@fb ~ 0$ /opt/rtcds/caltech/c1/target/fb/wiper.pl --delete
Tue Jan 7 23:09:21 PST 2014
Directory disk usage:
/frames/trend/minute_raw 385927520k
/frames/trend/second 125729084k
/frames/full 12552144324k
/frames/trend/minute 2311404k
Combined 13066112332k or 12759875m or 12460Gb
/frames size 13460088620k at 97.07%
/frames above keep value of 95.00%
Frame area size is 12401156668k
/frames/full size 12552144324k keep 11781098835k
/frames/trend/second size 125729084k keep 24802313k
/frames/trend/minute size 2311404k keep 620057k
Deleting some full frames to free 771045488k
- /frames/full/10685/C-R-1068567600-16.gwf
- /frames/full/10685/C-R-1068567616-16.gwf
...
controls@fb ~ 0$ df -h /frames
Filesystem Size Used Avail Use% Mounted on
/dev/sda1 13T 12T 826G 94% /frames
controls@fb ~ 0$
So it cleaned up 826G of space. It looks like the fb is stabilized for the moment. On site folks should confirm...
asdfasdfsadf sadf asdf |