40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Dec 20 01:24:11 2013, Den, Update, LSC, high bandwidth loop achieved for yarm CM_OL_meas.pdfcm_ol_sim.pdfCM_slow_fast_cross.pdf
    Reply  Fri Dec 20 03:31:07 2013, Koji, Update, LSC, lock acquisition path for the CM servo 
       Reply  Tue Apr 22 02:14:55 2014, ericq, Update, LSC, lock acquisition path for the CM servo 
    Reply  Fri Dec 20 03:34:40 2013, Koji, Update, LSC, high bandwidth loop achieved for yarm 
       Reply  Fri Dec 20 22:45:02 2013, Koji, Update, LSC, high bandwidth loop achieved for yarm 
Message ID: 9501     Entry time: Fri Dec 20 03:34:40 2013     In reply to: 9499     Reply to this: 9507
Author: Koji 
Type: Update 
Category: LSC 
Subject: high bandwidth loop achieved for yarm 

This too huge offset difference with/without "BOOST" switch should be checked.

ELOG V3.1.3-