Entry  Sat Dec 7 19:29:14 2013, Koji, Update, CDS, MEDM/ADL: replace rectangle with specified objects rectangle_config.pngrect_replace_result.png
    Reply  Fri Dec 13 13:45:50 2013, Koji, Update, CDS, MEDM/ADL: replace rectangle with specified objects screen_shot.png
Message ID: 9450     Entry time: Sat Dec 7 19:29:14 2013     Reply to this: 9466
Author: Koji 
Type: Update 
Category: CDS 
Subject: MEDM/ADL: replace rectangle with specified objects 

In order to unify the theme for MEDM screens, I'll have to make many combinations of rectangles, polygons, and invisible related-screen buttons.
Everytime I change the size of the block, I have to modify the size of this combination. It is impossile for me.

So, I made a script to replace a certain type of rectangles with a combination of the objects with the same (or related) size.

The script is here (so far)

/opt/rtcds/caltech/c1/medm/c1lsc/master/generateLSCscreen/rect_replace.py

Usage:

cat C1LSC_OVERVIEW_ADC.adl | ./rect_replace.py > tmp.adl

Description:

The script takes stdin and spits the result to stdout. It parses a given ADL file. When a "rectangle" object
with Channel A with a string "REPLACE_XXXX", it replaces it with the objects predefined as "XXXX".

So far, there is only "TYPE1" for the predefinition. It actually takes another argument to specify the
path of the related screen to open when the block is clicked. The path should be filled in "Channel B"
slot of the original rectangle. (See Attachment 1)

The "TYPE1" style has the function calls as indicated below. place_rect is to place a rectangle object. You can
specify the filling method and color. place_rel_disp is to place an invisible button with the link to the specified
path by strOpt. place_polygon places a polygon. The cordinate array for the polygon is described with
the relative positions from the specified position.

        place_rect(rect_x-4,         rect_y-4,        rect_w+7, rect_h+7, "outline",  0) # outline white box
        place_rel_disp(rect_x, rect_y, rect_w, rect_h, strOpt, 0, 14)                    # invisible button
        place_rect(rect_x,           rect_y,          rect_w,   rect_h,   "fill",     3) # main gray box
        place_rect(rect_x+3,         rect_y,          rect_w-6, 3,        "fill",     0) # top white rim
        place_rect(rect_x,           rect_y,          3,        rect_h-3, "fill",     0) # left white rim
        place_rect(rect_x+rect_w-3 , rect_y,          3,        rect_h,   "fill",    10) # right gray rim
        place_rect(rect_x,           rect_y+rect_h-3, rect_w-3, 3,        "fill",    10) # bottom gray rim
        place_polygon(rect_x+rect_w-3,rect_y,3,3, "fill",  0, [[0,0],[2,0],[0,2],[0,0]]) # top-right white triangle
        place_polygon(rect_x,rect_y+rect_h-3,3,3, "fill",  0, [[0,0],[2,0],[0,2],[0,0]]) # bottom-left white triangle

Attachment 1: rectangle_config.png  20 kB  | Hide | Hide all
rectangle_config.png
Attachment 2: rect_replace_result.png  3 kB  | Hide | Hide all
rect_replace_result.png