40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Dec 2 14:24:10 2013, Steve, Update, CDS, computer problems c1iscex.png1X6.JPG
    Reply  Tue Dec 3 17:08:06 2013, Koji, Update, CDS, computer problems 
       Reply  Wed Dec 4 12:02:39 2013, Koji, Update, CDS, FB restored 
Message ID: 9437     Entry time: Wed Dec 4 12:02:39 2013     In reply to: 9436
Author: Koji 
Type: Update 
Category: CDS 
Subject: FB restored 

Now FB is fixed: daqd and nds are running


When I rebooted FB, I noticed that any of the nfs file systems were not mounted.
I started tracking down the issues from here.

I googled the common issues of the nfs mounting during the boot sequence.
- It is good to give "_netdev" option to fstab to mount the system after the network connection is established.

- "auto" option specifies that the file system is mounted when mount -a is run

Resulting /etc/fstab is this:

/dev/sdb1                            /            ext3    noatime                    0 1
/swapfile                            none         swap    sw                         0 0
shm                                  /dev/shm     tmpfs   nodev,nosuid,noexec        0 0
/dev/sda1                            /frames      ext3    noatime                    0 0
linux1:/home/cds/                    /cvs/cds     nfs     _netdev,auto,rw,bg,soft    0 0
linux1:/home/cds/rtcds               /opt/rtcds   nfs     _netdev,auto,rw,bg,soft    0 0
linux1:/home/cds/rtapps              /opt/rtapps  nfs     _netdev,auto,rw,bg,soft    0 0
linux1:/home/cds/caltech/apps/linux  /opt/apps    nfs     _netdev,auto,rw,bg,soft    0 0

But this didn't help mounting the nfs file systems at boot yet. I dug into google again and found a command "/sbin/rc-update".
"/sbin/rc-update show" shows what services are activated at boot. It did not include "nfsmount". So the following command
was executed

 

> sudo /sbin/rc-update add nfsmount boot

> /sbin/rc-update show

* Broken runlevel entry: /etc/runlevels/boot/portmap
            bootmisc | boot                         
             checkfs | boot                         
           checkroot | boot                         
               clock | boot                         
         consolefont | boot                         
               dcron |      default                 
               dhcpd |      default                 
            hostname | boot                         
            in.tftpd | boot                         
             keymaps | boot                         
               local |      default nonetwork       
          localmount | boot                         
             modules | boot                         
               monit |      default                 
                  mx |      default                 
            net.eth0 |      default                 
              net.lo | boot                         
            netmount |      default                 
                 nfs | boot                         
            nfsmount | boot                         
          ntp-client | boot default                 
           rmnologin | boot                         
           rpc.statd | boot                         
                sshd | boot                         
           syslog-ng | boot                         
      udev-postmount |      default                 
             urandom | boot                         
              xinetd |      default

After rebooting, I confirmed that the nfs file systems are correctly mounted
and daqd and nds are automatically started.

This means that FB had never been configured to run correctly at boot. Shame on you!