40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Aug 12 21:27:03 2013, manasa, Update, CDS, c1iscex needs help 
    Reply  Tue Aug 13 07:40:53 2013, Steve, Update, CDS, c1iscex needs help c1iscexSick.png
       Reply  Tue Aug 13 17:20:54 2013, Koji, Update, CDS, [Fixed] c1iscex needs help 
          Reply  Mon Nov 25 10:57:14 2013, Koji, Update, CDS, woes on the X-end hosts Screenshot.png
             Reply  Mon Nov 25 12:57:54 2013, Jamie, Update, CDS, timing problem at c1iscex IO chassis 
                Reply  Mon Nov 25 17:28:33 2013, Jenne, Update, CDS, timing problem at c1iscex IO chassis 
                Reply  Wed Nov 27 14:45:49 2013, Jenne, Update, CDS, timing problem at c1iscex IO chassis 
                   Reply  Wed Nov 27 16:29:21 2013, Jenne, Update, CDS, Accidentally turned off SUS IO chassis 
                Reply  Mon Dec 2 16:04:47 2013, Jamie, Update, CDS, c1iscex timing problem mysteriously disappears??? (thanksgiving miracle???) festatus.png
                   Reply  Mon Dec 2 17:05:13 2013, Jenne, Update, CDS, c1iscex timing problem mysteriously disappears??? (thanksgiving miracle???) 
                      Reply  Tue Dec 3 07:42:23 2013, Steve, Update, CDS, c1iscex timing problem mysteriously disappears??? (thanksgiving miracle???) 
             Reply  Wed Dec 4 13:37:34 2013, Jenne, Update, CDS, c1auxex down again 
Message ID: 9429     Entry time: Wed Nov 27 16:29:21 2013     In reply to: 9428
Author: Jenne 
Type: Update 
Category: CDS 
Subject: Accidentally turned off SUS IO chassis 

[Jenne, Koji]

I was trying to lock the Yarm, and saw that I was not getting signals to go between the LSC and SCY models.  I had digital zeros for TRY, and when I overrode the trigger and tried to force signal to ETMY, I had digital zeros at the SUS-ETMY_LSC input. The corresponding filter bank in the rfm model was receiving signals, so the Dolphin connection between LSC and SUS was okay, it was just the RFM connection going to the end station that wasn't succeeding. 

Koji restarted the c1scy model, and then went inside the IFO room, and found that the SUS IO chassis power was offWe must have accidentally turned it off while we were in there earlier.  Koji turned on the power, and also restarted the rfm model, and we now have real signals going back and forth. 

Yarm is locked, ASS worked nicely, etc, etc, so things seem normal again (with the Yarm....ETMX stuff is still out of order).