Entry  Fri Nov 1 17:01:46 2013, Gabriele, Summary, LSC, Simulation of REFL_3f signal when the arms come in refl_3f_I_vs_cavity_tuning_noresf2.pngrefl_3f_I_vs_cavity_tuning.png
    Reply  Fri Nov 1 17:44:06 2013, Koji, Summary, LSC, Simulation of REFL_3f signal when the arms come in 
       Reply  Mon Nov 4 14:11:23 2013, Gabriele, Summary, LSC, Simulation of REFL_3f signal when the arms come in 
Message ID: 9327     Entry time: Fri Nov 1 17:44:06 2013     In reply to: 9326     Reply to this: 9337
Author: Koji 
Type: Summary 
Category: LSC 
Subject: Simulation of REFL_3f signal when the arms come in 

Yes, the resonance of the 2nd-order sidebands to the IFO screws up the 3f scheme.

2f (~22MHz) and 10f (~110MHz) are at x 5.6 and x 27.9 FSR from the carrier, so that's not the case.

Could we also see how much gain fluctuation of the 3f signals we would experience when the arm comes into the resonance?