Entry  Wed Oct 23 00:05:17 2013, manasa, Update, SUS, Unstable Y arm ALS points to problems with ETMY suspension Y-SUS_All.png
    Reply  Wed Oct 23 09:17:33 2013, Steve, Update, SUS, ETMY sensors compared to ETMX ETMYglitching.pngOSEMsensorsETMY&X.pngETMYgettingKickedUp.pngdrive-damp.png
       Reply  Wed Oct 23 11:42:28 2013, rana, Update, SUS, ETMY sensors compared to ETMX 
       Reply  Wed Oct 23 15:48:06 2013, rana, Update, SUS, ETMY sensors compared to ETMX remote-control-cockroach.jpg
          Reply  Wed Oct 23 17:30:17 2013, jamie, Update, SUS, ETMY sensors compared to ETMX 
             Reply  Wed Oct 23 18:24:56 2013, rana, Update, SUS, ETMY sensors compared to ETMX 
                Reply  Wed Oct 23 18:28:01 2013, Jenne, Update, SUS, ETMY sensors compared to ETMX Screenshot-Untitled_Window.pngScreenshot-Untitled_Window-1.png
                   Reply  Thu Oct 24 10:31:25 2013, Steve, Update, SUS, ETMY sensors compared to ETMX 24h_glitching.pngdampingOffref.png
                   Reply  Tue Oct 29 10:51:16 2013, Masayuki, Update, SUS, ETMY sensors compared to ETMX 
                   Reply  Tue Oct 29 22:33:57 2013, rana, Update, SUS, ETMY sensors compared to ETMX Scratch-n-SniffStinkyDooBabyShowerGame1.jpg
                      Reply  Wed Oct 30 14:58:44 2013, Steve, HowTo, General, shutting down a computer 
                Reply  Thu Oct 24 12:00:11 2013, jamie, Update, CDS, fb acquisition of slow channels  
                   Reply  Fri Oct 25 01:46:33 2013, rana, Update, CDS, fb acquisition of slow channels  
Message ID: 9311     Entry time: Tue Oct 29 22:33:57 2013     In reply to: 9268     Reply to this: 9319
Author: rana 
Type: Update 
Category: SUS 
Subject: ETMY sensors compared to ETMX 

Quote:

I've stopped the process of c1tst again to make it get better. At 9:20, I also went and opened the front rack door (the back one was already open). One reason its hot may be that the exhaust vents on the top of c1iscey are blocked by one of the custom multi-pin adaptor boxes. In the morning, we should drop the computer down by 1 or 2 notches in the rack so that it can air cool itself better. Make sure to poweroff the computer from the terminal before moving it though.

 After some torture Masayuki admitted that he and Steve ignored this elog and just turned off the power button. He blames Steve entirely.

to keep from damaging our computers and our data, NEVER DO THAT.