40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 9298     Entry time: Sun Oct 27 00:15:35 2013
Author: RANA 
Type: Update 
Category: SUS 
Subject: c1auxex 

 At some point tonight we lost our CA connection to c1auxex (which is actually the computer at the X End and controls the ETMX, but has a Y sticker). We could telnet to it, but its puny RAM must have been overloaded with too many EPICS connections that bypassed the CArepeater. I went around and booted some machines and it seems to be back and allowing damping now. Along the way I keyed off the crate to c1auxex a couple of times.

When trying to close the rack door I saw that Charlie/Steve had illegally connected the power cable for the illuminator through the door so that it couldn't close, so I disconnected it so that they can run it properly and feel better about themselves.

Disclaimer: Steve had nothing to do with this connection. I rerouted the cable the correct way. 10-28-2013

** what does this coherence tell us about the noise in the arms ?

Attachment 1: arms.pdf  215 kB  Uploaded Sun Oct 27 01:26:29 2013  | Hide | Hide all
arms.pdf
Attachment 2: arm-mc2-dewhite.pdf  254 kB  Uploaded Sun Oct 27 04:56:23 2013  | Hide | Hide all
arm-mc2-dewhite.pdf
ELOG V3.1.3-