Entry  Wed Sep 3 19:09:56 2008, Yoichi, DAQ, Computers, c1iovme power cycled 
    Reply  Thu Sep 4 00:38:14 2008, rana, Update, PSL, c1iovme power cycled 
       Reply  Thu Sep 4 07:29:52 2008, Yoichi, Update, PSL, c1iovme power cycled 
Message ID: 919     Entry time: Thu Sep 4 07:29:52 2008     In reply to: 918
Author: Yoichi 
Type: Update 
Category: PSL 
Subject: c1iovme power cycled 

Quote:
Entry 663 has a plot of this using the PSL/FSS/SLOWscan script. It shows that the SB's were ~8x smaller than the carrier.
P_carrier   J_0(Gamma)^2 
--------- = ------------
P_SB        J_1(Gamma)^2

Which I guess we have to solve numerically for large Gamma?


P_carrier/P_SB = 8 yields gamma=0.67.
ELOG V3.1.3-