Entry  Tue Jul 9 11:37:37 2013, gautam, Update, CDS, set up for testing DAC Interface-board pin outs 
    Reply  Tue Jul 9 12:01:20 2013, gautam, Update, CDS, set up for testing DAC Interface-board pin outs 
       Reply  Tue Jul 9 18:44:37 2013, gautam, Update, CDS, DAC Interface Board-Pin Outs DAC_Interface_Board_Pin-out.pdfbreak-out_ribbon.JPG
          Reply  Tue Jul 23 04:07:48 2013, gautam, Update, CDS, Excitation points set up on c1scx 
             Reply  Tue Jul 23 16:47:01 2013, gautam, Update, CDS, Excitation points set up on c1scx 
                Reply  Tue Jul 23 19:38:58 2013, gautam, Update, CDS, Characterisation of DAC at 1X9 
Message ID: 8911     Entry time: Tue Jul 23 19:38:58 2013     In reply to: 8909
Author: gautam 
Type: Update 
Category: CDS 
Subject: Characterisation of DAC at 1X9 

 

 I just finished carrying out the same checks for the DAC at 1X9 (with channels 9 through 16 that are unused as of now) as those I had done for the DAC at 1Y4, as the hardware prep up till now was done with the characterisation of the DAC at 1Y4. Conclusions:

  • The accessible range of output voltage are -10 V to +10V w.r.t ground --> No change needs to be made to the gain of the HV amplifier stage on the PZT Driver Board
  • The pin-outs of the DAC Adaptor Board at 1X9 is identical to that at 1Y4 --> Custom ribbons do not need to be modified.
  • The PSD of the DAC output has a peak at 64 kHz --> Notches on AI Board do not need to be moved again.

I will now proceed to install various pieces of hardware (AI Board, PZT driver board, HV Power Supply and cabling) at 1X9, while not making the connection to the PZTs till I receive the go ahead. 