40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu Jul 18 21:45:36 2013, Charles, Update, ISS, ISS - Full Schematic 40mServo_v1.pdf
    Reply  Wed Jul 24 22:58:03 2013, Charles, Update, ISS, ISS - Full Schematic - Updated 40mServo_v1.pdf
       Reply  Fri Jul 26 22:19:24 2013, Charles, Update, ISS, ISS - Full Schematic - Updated 40mServo_v1.pdf
Message ID: 8876     Entry time: Thu Jul 18 21:45:36 2013     Reply to this: 8920
Author: Charles 
Type: Update 
Category: ISS 
Subject: ISS - Full Schematic 

 Here I have included the full schematic (so far) of the proposed ISS. There are two sheets: the first schematic details the filter stages and their accompanying circuitry while the second schematic details the RMS threshold detection and subsequent triggering.

The first schematic is fairly self explanatory as to what different portions do, and I have annotated much of the second schematic as there are some non-traditional components etc.

I have not yet included some mechanism to adjust the threshold voltage in real time or any of the power regulation, but these should follow fairly quickly.

Attachment 1: 40mServo_v1.pdf  261 kB  Uploaded Mon Jul 22 12:34:09 2013  | Show | Show all
ELOG V3.1.3-