Author: Jenne 
Type: Update 
Category: CDS 
Subject: Proto-ASC implemented in ASS model 

I have implemented a proto-ASC in the ASS model.  

In an ASC block within the ASS model, I take in the POP QPD yaw, pit, and sum signals.  I ground the sum, since I don't have normalization yet (also, the QPD that we're using normalizes in the readout box already).  The pit and yaw signals each go through a filter bank, and then leave the sub-block so I can send the signals over to the SUS model, to push on PRM ASCPIT and ASCYAW. 

In doing this, I have removed the temporary PRM ASCYAW connection that Koji had made from the secret 11'th row of the LSC output matrix (see Koji's elog 8562 for details from when he implemented this stuff).

LSC, SUS and ASS were recompiled, and restarted.  I also restarted the daqd on the fb.