Entry  Wed Jun 19 02:46:19 2013, Jenne, Update, CDS, Connected ADC channels from IOO model to ASS model 
    Reply  Wed Jun 19 18:24:14 2013, Jenne, Update, CDS, Proto-ASC implemented in ASS model 
       Reply  Mon Jun 24 16:41:40 2013, Jenne, Update, CDS, Proto-ASC implemented in ASS model 
          Reply  Tue Jun 25 00:13:00 2013, Jenne, Update, CDS, Proto-ASC implemented in ASS model 
             Reply  Tue Jul 16 18:20:25 2013, Jenne, Update, CDS, Proto-ASC implemented in ASS model 
Message ID: 8722     Entry time: Wed Jun 19 02:46:19 2013     Reply to this: 8727
Author: Jenne 
Type: Update 
Category: CDS 
Subject: Connected ADC channels from IOO model to ASS model 

Following Jamie's table in elog 8654, I have connected up the channels 0, 1 and 2 from ADC0 on the IOO computer to rfm send blocks, which send the signals over to the rfm model, and then I use dolphin send blocks to get over to the ass model on the lsc machine. 

I'm using the 1st 3 channels on the Pentek Generic interface board, which is why I'm using channels 0,1,2. 

I compiled all 3 models (ioo, rfm, ass), and restarted them.  I also restarted the daqd on the fb, since I put in a temporary set of filter banks in the ass model, to use as sinks for the signal (since I haven't done anything else to the ASS model yet).

All 3 models were checked in to the svn.