Entry  Fri Apr 12 02:56:34 2013, Den, Update, Locking, prcl angular motion pointing.pngoplev_exc.pdf
    Reply  Fri Apr 12 09:20:32 2013, rana, Update, Locking, prcl angular motion 
       Reply  Fri Apr 12 13:21:34 2013, Den, Update, Locking, prcl angular motion 
          Reply  Sat Apr 13 03:45:51 2013, rana, Update, Locking, prcl angular motion 
             Reply  Sat Apr 13 23:11:04 2013, Den, Update, Locking, prcl angular motion pointing.pdf
                Reply  Sun Apr 14 17:56:03 2013, rana, Update, Locking, prcl angular motion 
                Reply  Mon May 13 18:44:04 2013, Jenne, Update, Locking, prcl angular motion TT_Q_measurements.pdf
Message ID: 8564     Entry time: Mon May 13 18:44:04 2013     In reply to: 8451
Author: Jenne 
Type: Update 
Category: Locking 
Subject: prcl angular motion 

I want to redo this estimate of where RIN comes from, since Den did this measurement before I put the lens in front of the POP PD. 

While thinking about his method of estimating the PR3 effect, I realized that we have measured numbers for the pendulum frequencies of the recycling cavity tip tilt suspensions. 

I have been secreting this data away for years.  My bad.  The relevant numbers for Tip Tilts #2 and #3 were posted in elog 3425, and for #4 in elog 3303.  However, the data for #s 1 and 5 were apparently never posted.  In elog 3447, I didn't put in numbers, but rather said that the data was taken.

Anyhow, attached is the data that was taken back in 2010.  Look to elog 7601 for which TT is installed where. 

 

Conclusion for the estimate of TT motion to RIN - the POS pendulum frequency is ~1.75Hz for the tip tilts, with a Q of ~2.

Attachment 1: TT_Q_measurements.pdf  120 kB  | Show | Show all