Author: Den 
Type: Update 
Category: Locking 
Subject: angular motion 

Spectra of BS, PRM, ITMX, ITMY are attached with oplevs ON and OFF (in units of urad). Loops reduce RMS from ~2urad to ~0.3urad but phase margin should be increased. REF traces show loop OFF. <-- really?

Note how PRM pitch and yaw spectra are different in the frequency range 0.5 - 7 Hz; yaw is factor of 50 larger then pitch at 2 Hz.