40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Tue Nov 13 11:30:54 2012, Manasa, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser
|
Tue Nov 13 16:18:51 2012, Manasa, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser : Circularize the 1W NPRO beam profile
|
Tue Nov 13 20:13:07 2012, Koji, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser : Circularize the 1W NPRO beam profile
|
Mon Nov 19 20:03:53 2012, Manasa, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser : ETMX layout on new table
|
Mon Nov 19 20:17:53 2012, Jenne, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser : ETMX layout on new table
|
Mon Nov 19 22:42:14 2012, Koji, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser : ETMX layout on new table
|
Tue Nov 20 11:40:19 2012, rana, Configuration, Green Locking, End table upgrade for auxiliary green laser : ETMX layout on new table
|
Wed Dec 12 11:04:45 2012, Manasa, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser : ETMX layout on new table
|
Thu Jan 10 12:41:06 2013, Manasa, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser : wiki page
|
Tue Mar 5 00:24:52 2013, Manasa, Configuration, 40m Upgrading, Endtable upgrade for auxiliary green laser : customized mount
|
Tue Mar 19 14:21:57 2013, Manasa, Update, 40m Upgrading, Endtable upgrade : INVENTORY
|
Tue Mar 19 19:19:50 2013, Jenne, Update, 40m Upgrading, Endtable upgrade : INVENTORY
|
Wed Mar 20 14:00:21 2013, Steve, Update, 40m Upgrading, Endtable upgrade
|
Wed Mar 20 15:51:54 2013, Manasa, Update, 40m Upgrading, Endtable upgrade
|
Thu Mar 21 08:11:53 2013, Steve, Update, 40m Upgrading, ETMY table swap
|
Thu Mar 21 08:46:46 2013, Manasa, Update, 40m Upgrading, ETMY table swap
|
Thu Mar 21 17:06:34 2013, Steve, Update, 40m Upgrading, ETMY table is out
|
Mon Mar 25 18:07:31 2013, Steve, Update, 40m Upgrading, ETMY table is out
|
Tue Mar 26 16:10:31 2013, Jamie, Update, 40m Upgrading, ETMY table leveling
|
Tue Mar 26 16:36:24 2013, Steve, Update, 40m Upgrading, table leveling mounts go here 
|
Fri Mar 29 16:30:27 2013, Steve, Update, 40m Upgrading, table leveling mounts go here
|
Fri Mar 29 16:35:54 2013, Steve, Update, 40m Upgrading, Endtable upgrade
|
Tue Apr 2 17:23:23 2013, Steve, Update, 40m Upgrading, new ETMY optical table & enclosure in place
|
Thu Apr 4 17:23:05 2013, Steve, Update, 40m Upgrading, ETMY optical table & enclosure is ready for optics
|
Fri Apr 5 01:18:34 2013, Manasa, Update, 40m Upgrading, Not a fan of the new plastic box yet
|
Sat Apr 6 09:21:36 2013, rana, Update, 40m Upgrading, Not a fan of the new plastic box yet
|
Mon Apr 8 16:37:26 2013, Steve, Update, 40m Upgrading, ETMY enclosure wall transmission
|
Mon Apr 22 17:43:09 2013, Steve, Update, 40m Upgrading, ETMY optical table & enclosure is ready for optics
|
Mon Apr 22 19:48:56 2013, Jenne, Update, 40m Upgrading, 4 pins enough?
|
Tue Apr 23 15:00:20 2013, Jenne, Update, 40m Upgrading, 4 pins enough?
|
Mon Mar 25 18:42:38 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : Timeline
|
Fri Mar 29 00:27:06 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : Assembly 
|
Fri Apr 5 01:28:56 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : populating the table
|
Tue Apr 9 00:15:18 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : populating the table
|
Wed Apr 10 14:25:04 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : LWE Alberto laser beam profile 
|
Wed Apr 17 02:20:13 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress 
|
Wed Apr 24 15:27:59 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress: New layout
|
Tue May 7 19:06:45 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress
|
Thu May 9 01:36:32 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress
|
Thu May 9 22:29:23 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress
|
Fri May 10 20:05:21 2013, Annalisa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress
|
Mon May 13 21:35:55 2013, Annalisa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress
|
Tue May 14 14:24:56 2013, Steve, Update, 40m Upgrading, enclosure removal
|
Thu May 16 08:32:05 2013, Steve, Update, 40m upgrading, ETMY op table disabled
|
Fri May 17 00:32:32 2013, Annalisa, Update, 40m upgrading, ETMY - progress
|
Fri May 17 15:38:51 2013, Steve, Update, 40m upgrading, ETMY enclosure is on the way back
|
Fri May 17 16:06:14 2013, rana, Update, 40m upgrading, ETMY op table disabled
|
Fri May 17 18:24:04 2013, Annalisa, Update, 40m upgrading, ETMY - progress
|
Thu May 23 00:16:32 2013, Annalisa, Update, 40m upgrading, ETMY - progress
|
Thu May 23 12:02:48 2013, Steve, Update, endtable upgrade, ETMY - oplev
|
Thu May 30 11:10:00 2013, Steve, Update, endtable upgrade, ETMY - oplev
|
Thu May 30 20:45:53 2013, Annalisa, Update, endtable upgrade, ETMY - oplev
|
Fri May 31 11:15:01 2013, Annalisa, Update, endtable upgrade, ETMY - Mode Matching for green - new calculation
|
Fri Sep 11 10:56:47 2015, Steve, Update, endtable upgrade, ETMY optical table feedthrough
|
Tue Sep 15 16:49:08 2015, Steve, Update, endtable upgrade, ETMY optical table feedthrough
|
Thu Sep 17 02:22:53 2015, Steve, Update, endtable upgrade, ETMY optical table feedthrough
|
Fri May 24 02:12:50 2013, Annalisa, Update, 40m upgrading, ETMY - Mode Matching for green  
|
Fri May 24 11:38:00 2013, Koji, Update, 40m upgrading, ETMY - Mode Matching for green
|
Fri May 24 12:50:25 2013, Annalisa, Update, 40m upgrading, ETMY - Mode Matching for green
|
Sat May 25 02:03:48 2013, Annalisa, Update, 40m upgrading, ETMY - Mode Matching for green - new calculation    
|
Mon May 27 21:38:53 2013, Annalisa, Update, 40m upgrading, ETMY - Beam Dumps
|
Tue May 28 22:11:23 2013, Annalisa, Update, 40m upgrading, ETMY - Yarm shutter cable
|
Tue May 21 17:03:45 2013, Steve, Update, endtable upgrade, enclosure tops are sealed   
|
Thu Jun 6 09:58:13 2013, Steve, Update, endtable upgrade, enclosure to chamber connection 
|
Tue Dec 22 16:39:42 2015, Steve, Update, endtable upgrade, ETMY optical table enclosure  
|
Tue May 14 21:03:15 2013, Annalisa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress
|
Wed May 15 21:27:39 2013, Annalisa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress
|
Thu May 2 01:19:41 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : progress
|
Tue Apr 9 00:32:57 2013, Manasa, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : TRY temporarily in place
|
Tue Apr 9 08:37:54 2013, Steve, Update, 40m Upgrading, Endtable upgrade for auxiliary green laser : TRY temporarily in place
|
Tue Apr 9 21:27:48 2013, Jenne, Update, 40m Upgrading, TRY temporarily in place
|
|
Message ID: 8318
Entry time: Wed Mar 20 15:51:54 2013
In reply to: 8315
Reply to this: 8320
|
Author: |
Manasa |
Type: |
Update |
Category: |
40m Upgrading |
Subject: |
Endtable upgrade |
|
|
Quote: |
As discussed at the 40m meeting: Koji, Manasa and Steve
We are planning to remove the whole 4'x2' optical table ETMY-ISCT with optics as it is tomorrow morning.
This way I can start placing the new 4'x3' table and acrylic enclosure in place.
|
I will be removing all cables on the ETMY endtable and labeling them today before we remove the table tomorrow morning. If there is anything else that should be done before the swapping which we might have not considered, elog it and we'll have it all done.
Also,I've attached the updated inventory. |
|