Entry  Mon Mar 11 14:10:05 2013, Jenne, Update, Environment, MC suspensions moved by this morning's earthquakes EQ.pngMC-SUS-kicked-EQ.png
    Reply  Mon Mar 11 15:52:46 2013, Jenne, Update, IOO, MC spots centered, WFS realigned MCspots_11Mar2013.png
    Reply  Mon Mar 11 17:18:00 2013, Manasa, Update, Environment, Earthquake: Suspensions tripped and MC realigned 
       Reply  Tue Mar 12 00:45:50 2013, Jenne, Update, IOO, MC weird again 
          Reply  Tue Mar 12 11:49:18 2013, Jenne, Update, IOO, MC weird again 
             Reply  Wed Mar 13 02:48:13 2013, Jenne, Update, IOO, MC all better 
Message ID: 8281     Entry time: Wed Mar 13 02:48:13 2013     In reply to: 8277
Author: Jenne 
Type: Update 
Category: IOO 
Subject: MC all better 

Koji reminded me (again....this is probably the  2nd or 3rd time I've "discovered" this, at least) that the script

..../scripts/MC/WFS/WFS_FilterBank_offsets

exists, and that we should use it sometimes.  See his elog 7452 for details. 

 

Notes about using this script:

* Only use it after MC has been very well aligned.  MC REFL DC should be less than 0.5 when the MC is locked (with the DC value ~4.5 with the MC unlocked, as usual).  This is hard to achieve, but important.  Also, check the MC spot centering.

* With the WFS servo off, but the MC locked and light on the WFS diodes, run the script. 