Entry  Wed Feb 27 00:56:01 2013, Jenne, Update, ASS, Motivation for reactivating the ASS 
    Reply  Wed Feb 27 02:21:55 2013, Jenne, Update, ASS, Motivation for reactivating the ASS 
Message ID: 8178     Entry time: Wed Feb 27 02:21:55 2013     In reply to: 8176
Author: Jenne 
Type: Update 
Category: ASS 
Subject: Motivation for reactivating the ASS 

I have modified the MeasureSpotPositions.py script to accept the arms as valid cavities (it used to give an error "Sorry, this only works for MC right now").

There is still no wrapper script to turn on lockins and turn them off after the measurement, so I have not tested the arm A2L yet.  But I should be able to tomorrow, or whenever the IFO is next available.

To-do:

* Write the wrapper script (analog of mcassMCdecenter).

* Fix arm assOff, assDown, assOn, assUp scripts to match the current channel names (which were changed long ago to be human-readable, versus mysterious numbers).

* Test.