40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Aug 8 13:29:54 2008, Yoichi, Update, SUS, No groove in the stand-off ... wait, it is not even a stand-off ! north-standoff-preview.jpgsouth-standoff-preview.jpgNo-groove.zip
    Reply  Fri Aug 8 15:10:35 2008, Yoichi, Update, SUS, No groove in the stand-off ... wait, it is not even a stand-off ! 
Message ID: 816     Entry time: Fri Aug 8 13:29:54 2008     Reply to this: 817
Author: Yoichi 
Type: Update 
Category: SUS 
Subject: No groove in the stand-off ... wait, it is not even a stand-off ! 
Yoichi, Steve, Seiji

We took magnified pictures of the stand-offs of the PRM.
Attm1: North side stand-off.
Attm2: South side stand-off.
Attm3: Zipped file of the full pictures.

We found no groove in the south side stand-off.
After some discussion, we concluded that it is actually a guide rod. You can see it from the size difference (the magnification is the same for the two pictures).
The stand off on the south side is missing (fell off, ran away, evaporated or whatever ...).
Also we noticed that the guide rod on the north side is missing.

We have to find a stand-off and place it on the south side.
Seiji suggested that it is better to put a guide rod next to the north side stand-off, otherwise the stand-off itself is too weak to hold the load.
He also said that the PRM was installed after he left, so it was not his fault.
Attachment 1: north-standoff-preview.jpg  40 kB  | Show | Show all
Attachment 2: south-standoff-preview.jpg  39 kB  | Show | Show all
Attachment 3: No-groove.zip  2.599 MB
ELOG V3.1.3-