Message ID: 8104     Entry time: Tue Feb 19 05:42:28 2013     In reply to: 8102     Reply to this: 8105
Author: Koji 
Type: Update 
Category: Electronics 
Subject: POP path set up but AS55 is broken 

10010 Ohm for POP55 vs 50 Ohm for AS55 (cf. http://nodus.ligo.caltech.edu:8080/40m/4763)

I wonder if you used an LED flash light, which emits no IR.