Thu Feb 7 12:56:18 2013, Jamie, Summary, General, PRC/arm mode matching calculations 8x
|
Thu Feb 7 17:10:11 2013, Koji, Summary, General, PRC/arm mode matching calculations
|
Fri Feb 8 00:23:33 2013, rana, Summary, General, PRC/arm mode matching calculations
|
Fri Feb 8 11:07:07 2013, Jamie, Summary, General, PRC/arm mode matching calculations
|
Fri Feb 8 12:42:45 2013, nicolas, Summary, General, PRC/arm mode matching calculations
|
|
Message ID: 8035
Entry time: Fri Feb 8 12:42:45 2013
In reply to: 8033
|
Author: |
nicolas |
Type: |
Summary |
Category: |
General |
Subject: |
PRC/arm mode matching calculations |
|
|
Quote: |
The main issue is that flipping PR3 induces considerable astigmatism.
|
Yes, at 45degrees PR3 will only have a curvature of about 850m for the vertical mode of the beam, apparently not enough to stabilize the cavity. |