Message ID: 7943     Entry time: Thu Jan 24 16:34:56 2013     In reply to: 7940
Author: rana 
Type: Update 
Category: General 
Subject: Laseroptik mirror - SN6 

  I have two questions:

1) Are we sure that the T measurement is not being compromised by some systematic? i.e. some leakage is making the apparent T appear too high.

2) IF the T is really so high, how should we decide whether or not to use this one rather than the G&H? Is the 532 nm property more important than the high recycling gain?