Entry  Sat Aug 18 19:29:56 2012, Den, Update, PEM, EM 172 microphones noise  em172.png
    Reply  Mon Dec 3 16:37:09 2012, Steve, Update, PEM, EM 172 microphones ordered 
Message ID: 7777     Entry time: Mon Dec 3 16:37:09 2012     In reply to: 7226
Author: Steve 
Type: Update 
Category: PEM 
Subject: EM 172 microphones ordered 

Quote:

I've put EM 172 microphones inside Steve's isolation box to measure their noise. I've attached mics to each other and aligned them using the tape.

At low frequencies (below 1 Hz) the noise is limited by ADC as there is a 10 Hz high-pass filter inside mic readout box.

ADC noise is measured by splitting the signal from 1 mic into 2 ADC channels.

em172.png

 BT EM172 microphones  are ordered.