Tue Nov 13 22:12:15 2012, Jenne, Update, IOO, Turn off MCL path before doing MC spot measurement
|
Wed Nov 14 09:01:42 2012, Dumb statement catcher, Update, IOO, Turn off MCL path before doing MC spot measurement
|
Wed Nov 14 13:58:18 2012, Jenne, Update, IOO, Turn off MCL path before doing MC spot measurement
|
|
Message ID: 7711
Entry time: Wed Nov 14 09:01:42 2012
In reply to: 7709
Reply to this: 7712
|
Author: |
Dumb statement catcher |
Type: |
Update |
Category: |
IOO |
Subject: |
Turn off MCL path before doing MC spot measurement |
|
|
Quote: |
We have discovered that the MCL loop squishes the length fluctuations that result from the MC spot measurement angular dither. This is good, in that the MCL is doing what it ought to do. However, we need to turn it off before doing a spot measurement.
|
This is totally non-sensical statement, of course.
We might also say that the DARM loop totally squishes the GW signal and so its better not to have any feedback in the interferometer. |