40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Wed Sep 26 17:09:15 2012, Den, Update, SUS, TT
|
Thu Sep 27 15:21:04 2012, Steve, Update, SUS, TT height adaptor & PTICH damping  
|
Fri Oct 12 10:39:45 2012, Steve, Update, SUS, TT PITCH damping
|
Fri Oct 12 14:01:33 2012, Koji, Update, SUS, TT PITCH damping
|
Fri Oct 12 16:59:26 2012, steve, Update, SUS, TT PITCH damping
|
Wed Oct 17 08:30:49 2012, Steve, Update, SUS, PTICH damping needed
|
Wed Oct 17 11:15:05 2012, Den, Update, SUS, PITCH damping needed
|
Thu Oct 18 02:42:38 2012, Den, Update, SUS, PITCH damping needed 7x
|
Fri Oct 19 18:30:07 2012, Den, Update, SUS, PITCH damping needed 
|
Sat Oct 20 01:23:56 2012, Den, Update, SUS, PITCH damping needed  
|
Sat Oct 20 20:37:55 2012, Den, Update, SUS, PITCH damping needed   
|
Mon Oct 22 11:26:12 2012, rana, Update, SUS, PITCH damping needed
|
Tue Oct 23 01:46:53 2012, Den, Update, SUS, PITCH damping needed 
|
Tue Oct 23 17:12:30 2012, Den, Update, SUS, PITCH damping needed
|
Wed Oct 24 01:02:10 2012, Koji, Update, SUS, PITCH damping needed
|
Mon Oct 29 18:14:55 2012, Den, Update, SUS, PITCH damping needed 
|
Tue Oct 23 18:18:29 2012, Jenne, Update, SUS, PITCH damping needed
|
|
Message ID: 7598
Entry time: Tue Oct 23 17:12:30 2012
In reply to: 7593
Reply to this: 7604
|
Author: |
Den |
Type: |
Update |
Category: |
SUS |
Subject: |
PITCH damping needed |
|
|
Koji and Steve pointed out that previous design of a damping bracket was a bit complicated to manufacture. So I made it simpler and also added a tap hole for original yaw damping. We'll give drawing to Mike in the machine shop tomorrow morning.
I've purchased K&J magnets for eddy current damping, they should be here in 2 days. |
|
|