Tue Oct 2 07:45:49 2012, Steve, Update, SUS, MC2 & PRM sus damping restored
|
Wed Oct 3 07:41:23 2012, Steve, Update, SUS, MC2 sus damping restored
|
Wed Oct 3 23:24:05 2012, Koji, Update, SUS, MC2 sus damping restored
|
Sun Oct 7 15:05:42 2012, Den, Update, SUS, MC2 sus damping restored
|
|
Message ID: 7496
Entry time: Sun Oct 7 15:05:42 2012
In reply to: 7466
|
Author: |
Den |
Type: |
Update |
Category: |
SUS |
Subject: |
MC2 sus damping restored |
|
|
Quote: |
This is the third morning in a row that the MC2 was tripped.
|
MC2 was tripped again. I think the answer is that watchdog's critical value was too small C1:SUS-MC2_PD_MAX_VAR = 10, so seismic could trip MC2. I've changed the value to 100.

|