40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Aug 24 22:01:15 2012, Jenne, Update, IOO, MC spot position - close MCdecenter_24Aug2012.png
    Reply  Sun Aug 26 12:26:44 2012, Jenne, Update, IOO, MC spot position - not done yet 
       Reply  Mon Aug 27 01:05:36 2012, Jenne, Update, IOO, MC spot position - callin' it quits MCdecenter_26Aug2012.png
          Reply  Mon Aug 27 12:03:54 2012, Koji, Update, IOO, MC spot position - callin' it quits 
             Reply  Mon Aug 27 18:32:48 2012, Jenne, Update, IOO, MC spot position - Jenne is stupid 
                Reply  Mon Aug 27 18:59:24 2012, jamie, Update, IOO, MC ASC screen was confusing - Jenne is not stupid Screenshot-1.pngScreenshot-2.png
                   Reply  Mon Aug 27 23:52:59 2012, Jenne, Update, IOO, MC Spots centered MCdecenter_26Aug2012.png
Message ID: 7290     Entry time: Mon Aug 27 23:52:59 2012     In reply to: 7289
Author: Jenne 
Type: Update 
Category: IOO 
Subject: MC Spots centered 

Finally!

Jamie and I have the MC spots centered.  We did the normal move the input beam, realign jazz for a while, then when we got close, used the "move MC2 spot" scripts to get the MC2 spot back to ~center.

This was way easier when the measurements were real, and not just noise.  Funny that.

The dark blue spot is the farthest from 0 in pitch, and it is 1.04mm.  The cyan and yellow we've done a pretty good job of getting them equally far from zero.  Since we aren't translating the beam, we can't get better than the point at which the cyan and yellow curves cross.

Attachment 1: MCdecenter_26Aug2012.png  185 kB  | Hide | Hide all
MCdecenter_26Aug2012.png
ELOG V3.1.3-