Author: Jamie 
Type: Update 
Category: CDS 
Subject: daqd and CDS network problems today 

When daqd is caught in this state it can not be killed.  It's in "uninterruptable sleep" ('D' state in the top output below).  This usually indicates that it's waiting for the kernel, usually due to some missing or hung IO.

  PID USER      PR  NI  VIRT  RES  SHR S %CPU %MEM    TIME+  COMMAND                                                                                      
28038 controls  20   0 4430m 2.0g  19m D    0 27.1   0:15.00 daqd                                                                                         

The memory footprint also seems to be getting big.  It's clearly trying to do something stupid that it can't handle.