Entry  Mon Aug 6 19:37:50 2012, Jamie, Update, CDS, daqd and CDS network problems today 
    Reply  Mon Aug 6 19:54:53 2012, Jamie, Update, CDS, daqd and CDS network problems today 
       Reply  Mon Aug 6 20:08:45 2012, Jamie, Update, CDS, daqd and CDS network problems today 
          Reply  Mon Aug 6 20:22:50 2012, Jamie, Update, CDS, daqd segfaulting after five minutes 
             Reply  Tue Aug 7 11:46:24 2012, Jamie, Update, CDS, Alex working on daqd 
                Reply  Tue Aug 7 14:17:07 2012, Jamie, Update, CDS, daqd running again; related to c1sup issue 
                   Reply  Tue Aug 7 14:34:01 2012, Jamie, Update, CDS, jk. daqd still segfaulting 
                      Reply  Tue Aug 7 15:04:23 2012, Jamie, Update, CDS, daqd problem was root-owned files and directories 
Message ID: 7094     Entry time: Mon Aug 6 19:54:53 2012     In reply to: 7093     Reply to this: 7095
Author: Jamie 
Type: Update 
Category: CDS 
Subject: daqd and CDS network problems today 

It looks like daqd is indeed caught in some bad state.  It seems to die at some point after making GPS corrections to minute trender:

...
[Mon Aug  6 19:45:13 2012] Minute trender made GPS time correction; gps=1028342727; gps%60=27
tail: `fb/logs/daqd.log' has been replaced;  following end of new file
263596
MX endpoint opened
startup file interpreter thread tid=140334118615312
calling yyparse(5, 6)
[Mon Aug  6 19:50:08 2012] ->5: #set avoid_reconnect
[Mon Aug  6 19:50:08 2012] ->5: set thread_stack_size=102400
[Mon Aug  6 19:50:08 2012] new threads will be created with the stack of size 102400K
[Mon Aug  6 19:50:08 2012] ->5: set allow_tpman_connect_fail
[Mon Aug  6 19:50:08 2012] ->5: #set dcu_status_check=5
[Mon Aug  6 19:50:08 2012] ->5: #set symm_gps_offset=-1
[Mon Aug  6 19:50:08 2012] ->5: #set symm_gps_offset=31535998
[Mon Aug  6 19:50:08 2012] ->5: ##set symm_gps_offset=347155213
[Mon Aug  6 19:50:08 2012] ->5: #set symm_gps_offset=378691215
[Mon Aug  6 19:50:08 2012] ->5: #set symm_gps_offset=378691212
[Mon Aug  6 19:50:08 2012] ->5: #set symm_gps_offset=315964799
[Mon Aug  6 19:50:08 2012] ->5: set symm_gps_offset=315964801
[Mon Aug  6 19:50:08 2012] ->5: set debug=0
[Mon Aug  6 19:50:08 2012] ->5: set log=2
[Mon Aug  6 19:50:08 2012] ->5: set zero_bad_data=0
[Mon Aug  6 19:50:08 2012] ->5: set dcu_status_check=9
[Mon Aug  6 19:50:08 2012] ->5: set controller_dcu=33
[Mon Aug  6 19:50:08 2012] ->5: set master_config="/opt/rtcds/caltech/c1/target/fb/master"
[Mon Aug  6 19:50:10 2012] finished configuring data channels
[Mon Aug  6 19:50:10 2012] ->5: configure channels begin end
Unable to find GDS node 90 system c1x00 in INI files
Unable to find GDS node 92 system c1tst2 in INI files
Unable to find GDS node 95 system c1x10 in INI files
[Mon Aug  6 19:50:10 2012] ->5: tpconfig "/opt/rtcds/caltech/c1/target/gds/param/testpoint.par"
[Mon Aug  6 19:50:10 2012] ->5: set gps_leaps = 820108813
[Mon Aug  6 19:50:10 2012] ->5: set detector_name="CIT"
[Mon Aug  6 19:50:10 2012] ->5: set detector_prefix="C1"
[Mon Aug  6 19:50:10 2012] ->5: set detector_longitude=-90.7742403889
[Mon Aug  6 19:50:10 2012] ->5: set detector_latitude=30.5628943337
[Mon Aug  6 19:50:10 2012] ->5: set detector_elevation=.0
[Mon Aug  6 19:50:10 2012] ->5: set detector_azimuths=1.1,4.7123889804
[Mon Aug  6 19:50:10 2012] ->5: set detector_altitudes=1.0,2.0
[Mon Aug  6 19:50:10 2012] ->5: set detector_midpoints=2000.0, 2000.0
[Mon Aug  6 19:50:10 2012] ->5: set num_dirs = 10
[Mon Aug  6 19:50:10 2012] ->5: set frames_per_dir=225
[Mon Aug  6 19:50:10 2012] ->5: set full_frames_per_file=1
[Mon Aug  6 19:50:10 2012] ->5: set full_frames_blocks_per_frame=16
[Mon Aug  6 19:50:10 2012] ->5: set frame_dir="/frames/full", "C-R-", ".gwf"
[Mon Aug  6 19:50:10 2012] ->5: set trend_num_dirs=10
[Mon Aug  6 19:50:10 2012] ->5: set trend_frames_per_dir=1440
[Mon Aug  6 19:50:10 2012] ->5: set trend_frame_dir= "/frames/trend/second", "C-T-", ".gwf"
[Mon Aug  6 19:50:10 2012] ->5: set raw-minute-trend-dir="/frames/trend/minute_raw"
[Mon Aug  6 19:50:10 2012] ->5: set nds-jobs-dir="/opt/rtcds/caltech/c1/target/fb"
[Mon Aug  6 19:50:10 2012] ->5: set minute-trend-num-dirs=10
[Mon Aug  6 19:50:10 2012] ->5: set minute-trend-frames-per-dir=24
[Mon Aug  6 19:50:10 2012] ->5: set minute-trend-frame-dir="/frames/trend/minute", "C-M-", ".gwf"
[Mon Aug  6 19:50:10 2012] ->5: start main 10
[Mon Aug  6 19:50:12 2012] main started
[Mon Aug  6 19:50:12 2012] ->5: start profiler
[Mon Aug  6 19:50:12 2012] ->5: # comment out this block to stop saving data
[Mon Aug  6 19:50:12 2012] frame saver started
[Mon Aug  6 19:50:12 2012] ->5: start frame-saver
[Mon Aug  6 19:50:13 2012] ->5: sync frame-saver
[Mon Aug  6 19:50:13 2012] ->5: start trender
[Mon Aug  6 19:50:13 2012] trender started
[Mon Aug  6 19:50:13 2012] trend frame saver started
[Mon Aug  6 19:50:13 2012] ->5: start trend-frame-saver
[Mon Aug  6 19:50:14 2012] ->5: sync trend-frame-saver
[Mon Aug  6 19:50:14 2012] minute trend frame saver started
[Mon Aug  6 19:50:14 2012] ->5: start minute-trend-frame-saver
[Mon Aug  6 19:50:14 2012] Done creating ADC structures
[Mon Aug  6 19:50:15 2012] ->5: sync minute-trend-frame-saver
[Mon Aug  6 19:50:15 2012] raw minute trend frame saver started
[Mon Aug  6 19:50:15 2012] ->5: start raw_minute_trend_saver
[Mon Aug  6 19:50:15 2012] ->5: #frame-writer "225.225.225.1" broadcast="131.215.113.0" all
[Mon Aug  6 19:50:15 2012] ->5: #sleep 5
[Mon Aug  6 19:50:15 2012] producer started
[Mon Aug  6 19:50:15 2012] ->5: start producer
[Mon Aug  6 19:50:15 2012] ->5: start epics dcu
[Mon Aug  6 19:50:15 2012] MX receiver thread started
[Mon Aug  6 19:50:15 2012] edcu started
[Mon Aug  6 19:50:15 2012] ->5: start epics server "C0:DAQ-DC0_" "C1:DAQ-DC0_"
[Mon Aug  6 19:50:15 2012] epics server started
[Mon Aug  6 19:50:15 2012] ->5: start listener 8087
[Mon Aug  6 19:50:15 2012] ->5: start listener 8088 1
[Mon Aug  6 19:50:15 2012] ->5: sleep 60
[Mon Aug  6 19:50:15 2012] Epics server started
[Mon Aug  6 19:50:15 2012] EDCU has 2553 channels configured; first=0

[Mon Aug  6 19:50:18 2012] Minute trender made GPS time correction; gps=1028343032; gps%60=32
...

The "tail:..." line indicates that the log was moved and replaced, which indicates a daqd restart.  As far as I know this was not manually triggered.

After the restart the same thing happens again.  About once every five minutes.

ELOG V3.1.3-