Entry  Mon Jul 30 12:38:45 2012, Jamie, Update, CDS, Move to RCG 2.5 tag release 
    Reply  Sun Aug 5 13:48:40 2012, Den, Update, CDS, Move to RCG 2.5 tag release erros.pngoaf.pngoverview.png
Message ID: 7086     Entry time: Sun Aug 5 13:48:40 2012     In reply to: 7049
Author: Den 
Type: Update 
Category: CDS 
Subject: Move to RCG 2.5 tag release 

Quote:

I moved the RCG to the advLigoRTS-2.5 tag

 After that RFM -> OAF communication through PCIE became bad again. Inside CommData2.c cache flushing is not allowed

// If PCIE comms show errors, may want to add this cache flushing
            #if 0
            if(ipcInfo[ii].netType == IPCIE)
                clflush_cache_range (ipcInfo[ii].pIpcData->dBlock[sendBlock][ipcIndex].data, 16);
            #endif

As a result, a significant part of MC_F and other signals is lost during RFM -> OAF transmission (270 - 330 out of 2048 per second)

erros.png   overview.png    oaf.png

 


Last time when I replaced 0 for 1, it suspended SUS machine because of the code bug. Alex modified a couple of files in the old version and it started to work. Do you know if this bug is fixed in the new version?