Quote: |
What is "DQF"? Is that the biquad? And what is the difference between DF1 and DF2? Why don't you just write out the name, so it's more clear.
|
DQF - biquad form
DF1 - direct form 1
DF2 - direct form 2
LNF - low-noise form
The difference between them is described in Matt's slides G0900928-v1. I think, LNF coefficients are incorrect in the presentation
|