Subject: PMC problems examined 

Quote:

WE found that the PMC EPICS values had not been toggled since the reboot and so the RF phase and Amplitude were totally wrong (we should replace this with a fixed oscillator box as we did with FSS).

Also, the NPRO SLOW slider was at -2 V which made the mode going into the PMC funny (although the mode was OK this morning before I started playing with the PMC sliders).

 PMC transmission is oscillating  in the range 0.5 - 0.85. PMC PZT voltage is 1-2 V.

FSS slow controls was -2.5 V. I adjusted it to 0 and PMC stabilized. PMC PZT voltage is 128, transmission is 0.845.

But most probably, slow control will drift again.

fss_slowm.png