40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 6968     Entry time: Thu Jul 12 15:25:24 2012
Author: Jenne 
Type: Update 
Category: SUS 
Subject: Clearing test points 

Somehow we got an excitation going on BS OpLevs, and even though Yuta thought he might have accidentally started it, he couldn't find where, so we couldn't stop it.

Since we don't have anything written on the wiki, I ended up calling Joe to remind me how to clear test points:

controls@allegra:~ 0$ diag -l -z
diag> tp clear * *
test point cleared
diag> awg clear 21.*
reset succeeded

The tp clear clears all test points everywhere.  The awg clear wouldn't let me do a universal clear, so I just did #21, which is the SUS model.  So if you want to kill excitations on a specific model, you must find it's DCU ID (it's in the top right corner of the GDS status screens for each model). 

ELOG V3.1.3-