Here's what I accomplished since my last elog:
I continued working on the beatbox calibration. Instead of using the function generator for an input signal,
I used the network analyzer because it can generate higher frequencies that are of more interest to us. I ran
the network analyzer output into the RF in port, and took voltage measurements from the Q port using the
oscilloscope. The frequency range I focused on was 100 - 200 MHz, and I also took more closely spaced measurements
from 180 - 200 MHz. The data is recorded on the computer now, and I will analyze it more fully in the future.
I also edited the Calibration page on the LIGO 40 m wiki. Rana showed me the page on calibration, but there was
limited information there, so he recommended that I post my work there as well. Right now I haven't posted much,
but I will likely add some information on the Simulink model I'm working on and results of measurements to be
taken as the project progresses.
The majority of my work has been on developing a Simulink model in Matlab of the differential arm length sensing
and control loop. I am using Figure 6-1 from Rana's thesis as a guide on important components to include in the
model. Some of the details on the transfer functions of components need to be worked out, but a basic framework has
been established. Right now the transfer function of the arm cavity is being approximated as a single pole, but
we may integrate the calibration model I'm working on with Sasha's work on the arm cavity. I have also begun to
implement the length response function in the model. I believe it is giving correct results at frequencies up to
100 Hz, but is off at higher frequencies. This might be fixed after I continue to fill in the transfer functions
of the digital components; they are currently set to 1 until I find more information on them. |