Entry  Tue Jul 3 17:56:35 2012, Jamie, Update, Green Locking, Laseroptik dichroic optics received 
    Reply  Tue Jul 3 19:04:59 2012, Jamie, Update, Green Locking, Laseroptik dichroic optics received 
Message ID: 6907     Entry time: Tue Jul 3 17:56:35 2012     Reply to this: 6909
Author: Jamie 
Type: Update 
Category: Green Locking 
Subject: Laseroptik dichroic optics received 

We have received the dichroic optics from Laseroptik.  The coatings are:

HR:

  • 532nm: T(s+p) > 97%
  • 1064nm:  R(p) > 99.9%

AR:

  • 532nm: R(s+p) < 1%
  • 1064nm: R(p) < 2%

We got two sets with these coatings:

  • 6x: 50 x 9.5mm, 2 degree wedge
  • 8x: 25 x 6.35mm, 2 degree wedge
  • 1x: 25 x 3mm, witness