Quote: |
I tried to restart c1ioo becuase I can't live without him.
I couldn't ssh or ping c1ioo, so I did hardware reboot.
c1ioo came back, but now ADC/DAC stats are all red.
c1ioo was OK until 3am when I left the control room last night. I don't know what happened, but StripTool from zita tells me that MC lock went off at around 4pm.
|
c1ioo was still all red on the CDS status screen, so I tried a couple of things.
mxstreamrestart (which aliases on the front ends to sudo /etc/init.d/mx_stream restart ) didn't help
sudo shutdown -r now didn't change anything either....c1ioo came back with red everywhere and 0x2bad on the IOP
eventually doing as Jamie did for c1sus in elog 6742, rtcds stop all , then rtcds start all fixed everything. Interestingly, when I tried rtcds start iop , I got the error
Cannot start/stop model 'iop' on host c1ioo , so I just tried rtcds start all , and that worked fine....started with c1x03, then c1ioo, then c1gcv.
|